A retrieval for characteristic raindrop size and width of the drop size distribution (DSD) based on triple-frequency vertical Doppler radar measurements is developed. The algorithm exploits a statistical relation that maps measurements of the differential Doppler velocities at X and Ka and at Ka and W bands into the two aforementioned DSD moments. The statistical mapping has been founded on 7,900 hr of disdrometer-observed DSDs and their simulated Doppler velocities. Additionally, a retrieval of Dm based only on DDVX−W measurements is also presented, and its performance is compared to the analogous algorithm exploiting DDVKa−W data. The retrievals are tested using triple-frequency radar data collected during a recent field campaign held at the Juelich Observatory for Cloud Evolution (JOYCE, Germany) where in situ measurements of the DSD were carried out only few meters away from the vertically pointing radars. The triple-frequency retrieval is able to obtain Dm with an uncertainty below 25% for Dm ranging from 0.7 to 2.4 mm. Compared to previously published dual-frequency retrievals, the third frequency does not improve the retrieval for small Dm (< 1.4 mm). However, it significantly surpasses the DDVKa−W algorithm for larger Dm (20% versus 50% bias at 2.25 mm). Also compared to DDVX−W method, the triple-frequency retrieval is found to provide an improvement of 15% in terms of bias for Dm = 2.25 mm. The triple-frequency retrieval of m performs with an uncertainty of 20–50% for 0.2 < m < 1.3 mm, with the best performance for 0.25 < m < 0.8 mm.

Triple‐Frequency Doppler Retrieval of Characteristic Raindrop Size / Mróz, Kamil; Battaglia, Alessandro; Kneifel, Stefan; D'Adderio, Leo Pio; Dias Neto, José. - In: EARTH AND SPACE SCIENCE. - ISSN 2333-5084. - 7:3(2020). [10.1029/2019EA000789]

Triple‐Frequency Doppler Retrieval of Characteristic Raindrop Size

Battaglia, Alessandro;
2020

Abstract

A retrieval for characteristic raindrop size and width of the drop size distribution (DSD) based on triple-frequency vertical Doppler radar measurements is developed. The algorithm exploits a statistical relation that maps measurements of the differential Doppler velocities at X and Ka and at Ka and W bands into the two aforementioned DSD moments. The statistical mapping has been founded on 7,900 hr of disdrometer-observed DSDs and their simulated Doppler velocities. Additionally, a retrieval of Dm based only on DDVX−W measurements is also presented, and its performance is compared to the analogous algorithm exploiting DDVKa−W data. The retrievals are tested using triple-frequency radar data collected during a recent field campaign held at the Juelich Observatory for Cloud Evolution (JOYCE, Germany) where in situ measurements of the DSD were carried out only few meters away from the vertically pointing radars. The triple-frequency retrieval is able to obtain Dm with an uncertainty below 25% for Dm ranging from 0.7 to 2.4 mm. Compared to previously published dual-frequency retrievals, the third frequency does not improve the retrieval for small Dm (< 1.4 mm). However, it significantly surpasses the DDVKa−W algorithm for larger Dm (20% versus 50% bias at 2.25 mm). Also compared to DDVX−W method, the triple-frequency retrieval is found to provide an improvement of 15% in terms of bias for Dm = 2.25 mm. The triple-frequency retrieval of m performs with an uncertainty of 20–50% for 0.2 < m < 1.3 mm, with the best performance for 0.25 < m < 0.8 mm.
File in questo prodotto:
File Dimensione Formato  
2020Triple2019EA000789ridotto.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.52 MB
Formato Adobe PDF
1.52 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2807052