Demand side management can be successfully applied to district heating systems for shaving thermal peaks. Peak shaving allows increasing share of convenient and less pollutant sources (waste heat, cogeneration and renewables) and enabling further building connections without modifying the pipelines. Demand side management in district heating is mainly done by shifting the load. Another interesting option consists in adjusting the substation regulation strategy; this approach not affects the heating schedule. This paper aims at analysing the opportunities for peak shaving using an innovative regulation strategy in the district heating substations, by controlling with a building model the effects on the indoor comfort conditions. The regulation strategy adopted is the Differential of Return Temperatures (DRT), that includes a constraint on the cold outlet section of the heat exchanger. This paper shows that thermal peak of building demand reducing on average of 15% by using the DRT regulation. Considering an entire distribution network, taking into account its thermal dynamics, the total peak request can be shaved of about 24%. Setting of the DRT regulation strategy has been shown being crucial for achieving satisfying peak shaving without compromising the indoor comfort conditions.
Demand side management in district heating systems by innovative control / Guelpa, E.; Marincioni, L.. - In: ENERGY. - ISSN 0360-5442. - 188:(2019), p. 116037. [10.1016/j.energy.2019.116037]
Demand side management in district heating systems by innovative control
Guelpa E.;Marincioni L.
2019
Abstract
Demand side management can be successfully applied to district heating systems for shaving thermal peaks. Peak shaving allows increasing share of convenient and less pollutant sources (waste heat, cogeneration and renewables) and enabling further building connections without modifying the pipelines. Demand side management in district heating is mainly done by shifting the load. Another interesting option consists in adjusting the substation regulation strategy; this approach not affects the heating schedule. This paper aims at analysing the opportunities for peak shaving using an innovative regulation strategy in the district heating substations, by controlling with a building model the effects on the indoor comfort conditions. The regulation strategy adopted is the Differential of Return Temperatures (DRT), that includes a constraint on the cold outlet section of the heat exchanger. This paper shows that thermal peak of building demand reducing on average of 15% by using the DRT regulation. Considering an entire distribution network, taking into account its thermal dynamics, the total peak request can be shaved of about 24%. Setting of the DRT regulation strategy has been shown being crucial for achieving satisfying peak shaving without compromising the indoor comfort conditions.File | Dimensione | Formato | |
---|---|---|---|
DRT.pdf
accesso aperto
Descrizione: Versione Pre-print articolo
Tipologia:
1. Preprint / submitted version [pre- review]
Licenza:
PUBBLICO - Tutti i diritti riservati
Dimensione
1.97 MB
Formato
Adobe PDF
|
1.97 MB | Adobe PDF | Visualizza/Apri |
Demand side management in district heating systems by innovative control.pdf
non disponibili
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
2.23 MB
Formato
Adobe PDF
|
2.23 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2787473