In this work, 3D non-destructive X-ray micro-CT tomography is used to analyze and reconstruct the internal structure of lyophilized samples, and CFD simulations for calculating their structural properties, i.e., porosity, pore diameter, tortuosity, and permeability.
CFD modelling based X-ray microtomography reconstruction of lyophilized products / Capozzi, Luigi C.; Novajra, Giorgia; VITALE BROVARONE, Chiara; Pisano, Roberto. - STAMPA. - 1:(2018), pp. 502-502. (Intervento presentato al convegno Freeze-Drying of Pharmaceuticals & Biologicals Conference tenutosi a Garmisch-Partenkirchen nel September 18-21).
CFD modelling based X-ray microtomography reconstruction of lyophilized products
Luigi C. CAPOZZI;Giorgia NOVAJRA;Chiara VITALE-BROVARONE;Roberto PISANO
2018
Abstract
In this work, 3D non-destructive X-ray micro-CT tomography is used to analyze and reconstruct the internal structure of lyophilized samples, and CFD simulations for calculating their structural properties, i.e., porosity, pore diameter, tortuosity, and permeability.| File | Dimensione | Formato | |
|---|---|---|---|
| FDPB-2018_capozzi_(POSTER).pdf accesso aperto 
											Descrizione: FDPB-2018_capozzi_(POSTER)
										 
											Tipologia:
											Abstract
										 
											Licenza:
											
											
												Pubblico - Tutti i diritti riservati
												
												
												
											
										 
										Dimensione
										154.62 kB
									 
										Formato
										Adobe PDF
									 | 154.62 kB | Adobe PDF | Visualizza/Apri | 
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2742814
			
		
	
	
	
			      	Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo