The interest in automatic modal parameter extraction techniques has increased significantly in recent years because of the rising demand for Continuous Structural Health Monitoring (CSHM) of civil structures and infrastructures. The wider use of CSHM is related to its capability for early damage detection and therefore to its usefulness for planning maintenance and strengthening interventions. This article presents the main steps followed in creating a robust routine to run on an online basis the first-ever Continuous Vibration-Based Structural Health Monitoring (CVB-SHM) of a large masonry oval dome, i.e., the dome of the Regina Montis Regalis Basilica, also known as Sanctuary of Vicoforte. The procedure uses an output-only stochastic subspace identification method complemented by an automatic analysis applied to identification results, which are typically provided in terms of stabilization diagrams. In this study, the fully automatic procedure also includes a hierarchical clustering algorithm to separate authentic from spurious modes.
An Automatic Modal Identification Procedure for the Permanent Dynamic Monitoring of the Sanctuary of Vicoforte / Pecorelli, Marica L.; Ceravolo, Rosario; Epicoco, Rodolfo. - In: INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE. - ISSN 1558-3058. - ELETTRONICO. - 14:4(2020), pp. 630-644. [10.1080/15583058.2018.1554725]
An Automatic Modal Identification Procedure for the Permanent Dynamic Monitoring of the Sanctuary of Vicoforte
Pecorelli, Marica L.;Ceravolo, Rosario;
2020
Abstract
The interest in automatic modal parameter extraction techniques has increased significantly in recent years because of the rising demand for Continuous Structural Health Monitoring (CSHM) of civil structures and infrastructures. The wider use of CSHM is related to its capability for early damage detection and therefore to its usefulness for planning maintenance and strengthening interventions. This article presents the main steps followed in creating a robust routine to run on an online basis the first-ever Continuous Vibration-Based Structural Health Monitoring (CVB-SHM) of a large masonry oval dome, i.e., the dome of the Regina Montis Regalis Basilica, also known as Sanctuary of Vicoforte. The procedure uses an output-only stochastic subspace identification method complemented by an automatic analysis applied to identification results, which are typically provided in terms of stabilization diagrams. In this study, the fully automatic procedure also includes a hierarchical clustering algorithm to separate authentic from spurious modes.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2721559
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo