OBJECTIVES: To determine whether (1) computer-based self-training for CT colonography (CTC) improves interpretation performance of novice readers; (2) computer-aided detection (CAD) use during training affects learning. METHODS: Institutional review board approval and patients' informed consent were obtained for all cases included in this study. Twenty readers (17 radiology residents, 3 radiologists) with no experience in CTC interpretation were recruited in three centres. After an introductory course, readers performed a baseline assessment test (37 cases) using CAD as second reader. Then they were randomized (1:1) to perform either a computer-based self-training (150 cases verified at colonoscopy) with CAD as second reader or the same training without CAD. The same assessment test was repeated after completion of the training programs. Main outcome was per lesion sensitivity (≥ 6 mm). A generalized estimating equation model was applied to evaluate readers' performance and the impact of CAD use during training. RESULTS: After training, there was a significant improvement in average per lesion sensitivity in the unassisted phase, from 74% (356/480) to 83% (396/480) (p < 0.001), and in the CAD-assisted phase, from 83% (399/480) to 87% (417/480) (p = 0.021), but not in average per patient sensitivity, from 93% (390/420) to 94% (395/420) (p = 0.41), and specificity, from 81% (260/320) to 86% (276/320) (p = 0.15). No significant effect of CAD use during training was observed on per patient sensitivity and specificity, nor on per lesion sensitivity. CONCLUSIONS: A computer-based self-training program for CTC improves readers' per lesion sensitivity. CAD as second reader does not have a significant impact on learning if used during training.

Computer-based self-training for CT colonography with and without CAD / Sali, Lapo; Delsanto, Silvia; Sacchetto, Daniela; Correale, Loredana; Falchini, Massimo; Ferraris, Andrea; Gandini, Giovanni; Grazzini, Giulia; Iafrate, Franco; Iussich, Gabriella; Morra, Lia; Laghi, Andrea; Mascalchi, Mario; Regge, Daniele. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - STAMPA. - 28:11(2018), pp. 4783-4791. [10.1007/s00330-018-5480-5]

Computer-based self-training for CT colonography with and without CAD

Delsanto, Silvia;Morra, Lia;
2018

Abstract

OBJECTIVES: To determine whether (1) computer-based self-training for CT colonography (CTC) improves interpretation performance of novice readers; (2) computer-aided detection (CAD) use during training affects learning. METHODS: Institutional review board approval and patients' informed consent were obtained for all cases included in this study. Twenty readers (17 radiology residents, 3 radiologists) with no experience in CTC interpretation were recruited in three centres. After an introductory course, readers performed a baseline assessment test (37 cases) using CAD as second reader. Then they were randomized (1:1) to perform either a computer-based self-training (150 cases verified at colonoscopy) with CAD as second reader or the same training without CAD. The same assessment test was repeated after completion of the training programs. Main outcome was per lesion sensitivity (≥ 6 mm). A generalized estimating equation model was applied to evaluate readers' performance and the impact of CAD use during training. RESULTS: After training, there was a significant improvement in average per lesion sensitivity in the unassisted phase, from 74% (356/480) to 83% (396/480) (p < 0.001), and in the CAD-assisted phase, from 83% (399/480) to 87% (417/480) (p = 0.021), but not in average per patient sensitivity, from 93% (390/420) to 94% (395/420) (p = 0.41), and specificity, from 81% (260/320) to 86% (276/320) (p = 0.15). No significant effect of CAD use during training was observed on per patient sensitivity and specificity, nor on per lesion sensitivity. CONCLUSIONS: A computer-based self-training program for CTC improves readers' per lesion sensitivity. CAD as second reader does not have a significant impact on learning if used during training.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2708511
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo