The general tokamak thermal-hydraulic model (GETTHEM) has been updated to the most recent version of the EU DEMO helium-cooled pebble bed breeding blanket (BB) design. The GETTHEM results are first benchmarked in a controlled case against the results of 3-D computational fluid-dynamics computations, showing an acceptable accuracy despite the inherent simplifications in the GETTHEM model. GETTHEM is then applied to the evaluation of the poloidal hot spot temperature distribution in an entire BB segment, showing that the maximum temperature in the EUROFER structures overcomes the design limit of 550 °C by more than 50 °C in some blanket modules. A possible mitigation strategy is then proposed and analyzed, based on the idea of cooling the first wall in parallel with the breeding zone, showing that this solution would allow having the EUROFER in its working temperature range in the entire segment, although at the expense of a larger pressure drop.
Thermal-Hydraulic Analysis of the EU DEMO Helium-Cooled Pebble Bed Breeding Blanket Using the GETTHEM Code / Froio, Antonio; Cismondi, Fabio; Savoldi, Laura; Zanino, Roberto. - In: IEEE TRANSACTIONS ON PLASMA SCIENCE. - ISSN 0093-3813. - STAMPA. - 46:5(2018), pp. 1436-1445. [10.1109/TPS.2018.2791678]
Thermal-Hydraulic Analysis of the EU DEMO Helium-Cooled Pebble Bed Breeding Blanket Using the GETTHEM Code
Froio, Antonio;Savoldi, Laura;Zanino, Roberto
2018
Abstract
The general tokamak thermal-hydraulic model (GETTHEM) has been updated to the most recent version of the EU DEMO helium-cooled pebble bed breeding blanket (BB) design. The GETTHEM results are first benchmarked in a controlled case against the results of 3-D computational fluid-dynamics computations, showing an acceptable accuracy despite the inherent simplifications in the GETTHEM model. GETTHEM is then applied to the evaluation of the poloidal hot spot temperature distribution in an entire BB segment, showing that the maximum temperature in the EUROFER structures overcomes the design limit of 550 °C by more than 50 °C in some blanket modules. A possible mitigation strategy is then proposed and analyzed, based on the idea of cooling the first wall in parallel with the breeding zone, showing that this solution would allow having the EUROFER in its working temperature range in the entire segment, although at the expense of a larger pressure drop.File | Dimensione | Formato | |
---|---|---|---|
DEMO_HCPB_GETTHEM_SOFE_review_final.pdf
accesso aperto
Descrizione: Post-print
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
2.13 MB
Formato
Adobe PDF
|
2.13 MB | Adobe PDF | Visualizza/Apri |
08264809.pdf
accesso riservato
Descrizione: Versione editoriale
Tipologia:
2a Post-print versione editoriale / Version of Record
Licenza:
Non Pubblico - Accesso privato/ristretto
Dimensione
3.39 MB
Formato
Adobe PDF
|
3.39 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2698095