Proper muscle activity quantification is highly relevant to monitor and treat spastic cocontraction. As activity may distribute unevenly within muscle volumes, particularly for pennate calf muscles, surface electromyograms (EMGs) detected by traditional bipolar montage may provide biased estimations of muscle activity. We compared cocontraction estimates obtained using bipolar vs grids of electrodes (high-density EMG, HD-EMG). EMGs were collected from medial gastrocnemius, soleus and tibialis anterior during isometric plantar and dorsi-flexion efforts at three levels (30%, 70% and 100% MVC), knee flexed and extended. Cocontraction index (CCI) was estimated separately for each electrode pair in the grid. While soleus and tibialis anterior CCI estimates did not depend on the detection system considered, for gastrocnemius bipolar electrodes provided larger cocontraction estimates than HD-EMG at highest effort levels, at both knee angles (ANOVA; P <.001). Interestingly, HD-EMG detected greater gastrocnemius EMGs distally during plantar flexions, and greater CCI values proximally during dorsiflexions. These results suggest that bipolar electrodes: (i) provide reliable estimates of soleus and tibialis anterior cocontraction; (ii) may under-or overestimate gastrocnemius cocontraction, depending on their distal or proximal position.

Localised sampling of myoelectric activity may provide biased estimates of cocontraction for gastrocnemius though not for soleus and tibialis anterior muscles / Vinti, Maria; Gracies, Jean-Michel; Gazzoni, Marco; Vieira, Taian. - In: JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY. - ISSN 1050-6411. - STAMPA. - 38:(2018), pp. 34-43. [10.1016/j.jelekin.2017.11.003]

Localised sampling of myoelectric activity may provide biased estimates of cocontraction for gastrocnemius though not for soleus and tibialis anterior muscles

Gazzoni, Marco;Vieira, Taian
2018

Abstract

Proper muscle activity quantification is highly relevant to monitor and treat spastic cocontraction. As activity may distribute unevenly within muscle volumes, particularly for pennate calf muscles, surface electromyograms (EMGs) detected by traditional bipolar montage may provide biased estimations of muscle activity. We compared cocontraction estimates obtained using bipolar vs grids of electrodes (high-density EMG, HD-EMG). EMGs were collected from medial gastrocnemius, soleus and tibialis anterior during isometric plantar and dorsi-flexion efforts at three levels (30%, 70% and 100% MVC), knee flexed and extended. Cocontraction index (CCI) was estimated separately for each electrode pair in the grid. While soleus and tibialis anterior CCI estimates did not depend on the detection system considered, for gastrocnemius bipolar electrodes provided larger cocontraction estimates than HD-EMG at highest effort levels, at both knee angles (ANOVA; P <.001). Interestingly, HD-EMG detected greater gastrocnemius EMGs distally during plantar flexions, and greater CCI values proximally during dorsiflexions. These results suggest that bipolar electrodes: (i) provide reliable estimates of soleus and tibialis anterior cocontraction; (ii) may under-or overestimate gastrocnemius cocontraction, depending on their distal or proximal position.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2697781
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo