A new macroelement model is presented in this paper for the simulation of the in-plane (IP) and out-of-plane (OOP) response of infilled frames subjected to seismic actions. The model consists of two diagonal, one horizontal, and one vertical struts. Each strut is represented by two fiber-section beam-column elements. The model is able to capture the arching action of the wall under an OOP load as well as the interaction between the IP and OOP actions. The proposed modeling approach is sufficiently simple and efficient that it can be used for the static or dynamic analysis of an entire structural system. An experimental validation has been carried out. A further numerical study performed with the macroelement model has shown that wall damage due to IP loads can significantly reduce the OOP resistance of the wall, and this influence depends on the slenderness (height/thickness) of the wall. A more slender wall will suffer a more significant loss of OOP resistance.

Macroelement Model for In-Plane and Out-of-Plane Responses of Masonry Infills in Frame Structures / DI TRAPANI, Fabio; Shing, P. B.; Cavaleri, L.. - In: JOURNAL OF STRUCTURAL ENGINEERING. - ISSN 0733-9445. - STAMPA. - 144:2(2018), pp. 1-13. [10.1061/(ASCE)ST.1943-541X.0001926]

Macroelement Model for In-Plane and Out-of-Plane Responses of Masonry Infills in Frame Structures

Fabio Di Trapani;
2018

Abstract

A new macroelement model is presented in this paper for the simulation of the in-plane (IP) and out-of-plane (OOP) response of infilled frames subjected to seismic actions. The model consists of two diagonal, one horizontal, and one vertical struts. Each strut is represented by two fiber-section beam-column elements. The model is able to capture the arching action of the wall under an OOP load as well as the interaction between the IP and OOP actions. The proposed modeling approach is sufficiently simple and efficient that it can be used for the static or dynamic analysis of an entire structural system. An experimental validation has been carried out. A further numerical study performed with the macroelement model has shown that wall damage due to IP loads can significantly reduce the OOP resistance of the wall, and this influence depends on the slenderness (height/thickness) of the wall. A more slender wall will suffer a more significant loss of OOP resistance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2693791
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo