To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset. Methods Twenty-one radiologists assessed 613 screening/ diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (κ) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification. Results While the agreement of individual radiologists with the PMR ranged from κ=0.483 to κ=0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (κ=0.620, standard deviation [SD]=0.140), individual versus PMR (κ=0.736, SD=0.117), and individual versus ABDE (κ=0.674, SD=0.095). Agreement between ABDE and PMR was almost perfect (κ=0.831). Conclusions The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation.

Mammographic density: Comparison of visual assessment with fully automatic calculation on a multivendor dataset / Sacchetto, Daniela; Morra, Lia; Agliozzo, Silvano; Bernardi, Daniela; Bjoerklund, TOMAS PER ROLF; Brancato, Beniamino; Bravetti, Patrizia; Carbonaro, Luca A.; Correale, Loredana; Fantã², Carmen; Favettini, Elisabetta; Martincich, Laura; Milanesio, Luisella; Mombelloni, Sara; Monetti, Francesco; Morrone, Doralba; Pellegrini, Marco; Pesce, Barbara; Petrillo, Antonella; Saguatti, Gianni; Stevanin, Carmen; Trimboli, Rubina M.; Tuttobene, Paola; Valentini, Marvi; Marra, Vincenzo; Frigerio, Alfonso; Bert, Alberto; Sardanelli, Francesco. - In: EUROPEAN RADIOLOGY. - ISSN 0938-7994. - ELETTRONICO. - 26:1(2015), pp. 175-183. [10.1007/s00330-015-3784-2]

Mammographic density: Comparison of visual assessment with fully automatic calculation on a multivendor dataset

MORRA, LIA;BJOERKLUND, TOMAS PER ROLF;
2015

Abstract

To compare breast density (BD) assessment provided by an automated BD evaluator (ABDE) with that provided by a panel of experienced breast radiologists, on a multivendor dataset. Methods Twenty-one radiologists assessed 613 screening/ diagnostic digital mammograms from nine centers and six different vendors, using the BI-RADS a, b, c, and d density classification. The same mammograms were also evaluated by an ABDE providing the ratio between fibroglandular and total breast area on a continuous scale and, automatically, the BI-RADS score. A panel majority report (PMR) was used as reference standard. Agreement (κ) and accuracy (proportion of cases correctly classified) were calculated for binary (BI-RADS a-b versus c-d) and 4-class classification. Results While the agreement of individual radiologists with the PMR ranged from κ=0.483 to κ=0.885, the ABDE correctly classified 563/613 mammograms (92 %). A substantial agreement for binary classification was found for individual reader pairs (κ=0.620, standard deviation [SD]=0.140), individual versus PMR (κ=0.736, SD=0.117), and individual versus ABDE (κ=0.674, SD=0.095). Agreement between ABDE and PMR was almost perfect (κ=0.831). Conclusions The ABDE showed an almost perfect agreement with a 21-radiologist panel in binary BD classification on a multivendor dataset, earning a chance as a reproducible alternative to visual evaluation.
File in questo prodotto:
File Dimensione Formato  
Sacchetto2016_Article_MammographicDensityComparisonO.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 512.1 kB
Formato Adobe PDF
512.1 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2687098