We report on the detection of an angiogenic molecule Vascular Endothelial Growth Factor (VEGF) in different biological matrices by means of a new integrated biosensing platform exploiting the properties of Bloch surface waves. The new platform takes advantage of a tandem configuration, in which both label-free and enhanced fluorescence detection are implemented. Specifically designed one dimensional photonic crystals were deposited directly on disposable and low cost plastic biochips. A direct sandwich immunoassay was used to detect VEGF in buffer, cell culture supernatant and human plasma at low concentration (ng/mL). The platform enabled the detection of VEGF in all three matrices with high resolution, fast turnaround time (30 min) and in close agreement with the results of enzyme linked immunosorbent assays.

Bloch surface wave label-free and fluorescence platform for the detection of VEGF biomarker in biological matrices / Rizzo, Riccardo; Alvaro, Maria; Danz, Norbert; Napione, Lucia; Descrovi, Emiliano; Schmieder, Stefan; Sinibaldi, Alberto; Chandrawati, Rona; Rana, Subinoy; Munzert, Peter; Schubert, Thomas; Maillart, Emmanuel; Anopchenko, Aleksei; Rivolo, Paola; Mascioletti, Alessandro; Sonntag, Frank; Stevens, Molly M.; Bussolino, Federico; Michelotti, Francesco. - In: SENSORS AND ACTUATORS. B, CHEMICAL. - ISSN 0925-4005. - STAMPA. - 255:(2018), pp. 2143-2150. [10.1016/j.snb.2017.09.018]

Bloch surface wave label-free and fluorescence platform for the detection of VEGF biomarker in biological matrices

RIZZO, RICCARDO;NAPIONE, LUCIA;DESCROVI, EMILIANO;RIVOLO, PAOLA;
2018

Abstract

We report on the detection of an angiogenic molecule Vascular Endothelial Growth Factor (VEGF) in different biological matrices by means of a new integrated biosensing platform exploiting the properties of Bloch surface waves. The new platform takes advantage of a tandem configuration, in which both label-free and enhanced fluorescence detection are implemented. Specifically designed one dimensional photonic crystals were deposited directly on disposable and low cost plastic biochips. A direct sandwich immunoassay was used to detect VEGF in buffer, cell culture supernatant and human plasma at low concentration (ng/mL). The platform enabled the detection of VEGF in all three matrices with high resolution, fast turnaround time (30 min) and in close agreement with the results of enzyme linked immunosorbent assays.
File in questo prodotto:
File Dimensione Formato  
biloba1_ SENS_ACTUATOR B_ final_1-s2.0-S0925400517316829-main.pdf

accesso riservato

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.69 MB
Formato Adobe PDF
1.69 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2687025
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo