In the recent large earthquakes in Chile, New Zealand, and Japan, a great number of critical facilities, including hospitals, schools, bridges, factories, airports, and utility systems, experienced extensive damage resulting in their loss of their function, and consequently substantial economic losses. Heavily affected communities were paralyzed for months following these large seismic events. The recovery process is estimated to last from several years to few decades. As a result, increased attention is being placed on strategies to design facilities that are both safe and damage resistant. It is often presumed that such an approach increases costs to an unacceptable level. The study reported herein compares the repair costs and repair times considering two designs for a typical three-story steel building: conventional fixed-base and damage resistant base-isolated moment resisting frame system. Performance-based earthquake evaluation tools are used to estimate repair costs and times for five different hazard levels considering two occupancy types critical for recovery: healthcare and school. The buildings are located in a seismic region in western North America. It is shown that using seismic isolation to enhance damage resistance results in significantly smaller repair cost, repair time, and improved resilience for the base-isolated alternative compared to a conventional fixed-base design.

Utilizing Base-isolation Systems to Increase Earthquake Resiliency of Healthcare and School Buildings / Moretti, Sarah; Trozzo, Alba; Terzic, Vesna; Cimellaro, GIAN PAOLO; Mahin, Stephen. - In: PROCEDIA ECONOMICS AND FINANCE. - ISSN 2212-5671. - ELETTRONICO. - 18:(2014), pp. 969-976. [10.1016/S2212-5671(14)01024-7]

Utilizing Base-isolation Systems to Increase Earthquake Resiliency of Healthcare and School Buildings

CIMELLARO, GIAN PAOLO;
2014

Abstract

In the recent large earthquakes in Chile, New Zealand, and Japan, a great number of critical facilities, including hospitals, schools, bridges, factories, airports, and utility systems, experienced extensive damage resulting in their loss of their function, and consequently substantial economic losses. Heavily affected communities were paralyzed for months following these large seismic events. The recovery process is estimated to last from several years to few decades. As a result, increased attention is being placed on strategies to design facilities that are both safe and damage resistant. It is often presumed that such an approach increases costs to an unacceptable level. The study reported herein compares the repair costs and repair times considering two designs for a typical three-story steel building: conventional fixed-base and damage resistant base-isolated moment resisting frame system. Performance-based earthquake evaluation tools are used to estimate repair costs and times for five different hazard levels considering two occupancy types critical for recovery: healthcare and school. The buildings are located in a seismic region in western North America. It is shown that using seismic isolation to enhance damage resistance results in significantly smaller repair cost, repair time, and improved resilience for the base-isolated alternative compared to a conventional fixed-base design.
File in questo prodotto:
File Dimensione Formato  
140610_PAPER.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Creative commons
Dimensione 269.24 kB
Formato Adobe PDF
269.24 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2652908
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo