Maintaining suitable microclimate internal conditions in retails store is of great importance, because thermal comfort needs to be satisfied for both customers and employees. In the present work, energy consumptions and microclimate quality assessment of a retail store are shown. Buildings dynamic simulation tool, and energy and environmental monitoring were both used for the building climate quality and energy efficiency investigation. The paper shows how monitoring data, combined with dynamic simulation, allow to improve the correct system control increasing energy efficiency, and enhancing moreover the indoor thermal comfort in retails.
Energy Consumption and Thermal Comfort Assessment in Retail Stores: Monitoring and Dynamic Simulation Applied to a Case Study in Turin / Raimondo, Daniela; Bassu, A.; Corgnati, STEFANO PAOLO; Trifirò, A.. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - 78:(2015), pp. 1015-1020. [10.1016/j.egypro.2015.11.049]
Energy Consumption and Thermal Comfort Assessment in Retail Stores: Monitoring and Dynamic Simulation Applied to a Case Study in Turin
RAIMONDO, DANIELA;CORGNATI, STEFANO PAOLO;
2015
Abstract
Maintaining suitable microclimate internal conditions in retails store is of great importance, because thermal comfort needs to be satisfied for both customers and employees. In the present work, energy consumptions and microclimate quality assessment of a retail store are shown. Buildings dynamic simulation tool, and energy and environmental monitoring were both used for the building climate quality and energy efficiency investigation. The paper shows how monitoring data, combined with dynamic simulation, allow to improve the correct system control increasing energy efficiency, and enhancing moreover the indoor thermal comfort in retails.File | Dimensione | Formato | |
---|---|---|---|
Corgnati et all_Energy Consum and Therm Comf Ass in Retail Stor Monit and Dyn Sim Ap to a Case Study in Turin.pdf
accesso aperto
Descrizione: Corgnati et all_Energy Consum and Therm Comf Ass in Retail Stor Monit and Dyn Sim Ap to a Case Study in Turin
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Creative commons
Dimensione
695.41 kB
Formato
Adobe PDF
|
695.41 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2638208
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo