In the field of freeze drying of pharmaceutics the homogeneity of the sublimation flux during drying is fundamental to allow a final product with the same characteristics. Previous studies have shown that the control of freezing stage, in addition to a dramatic reduction of cycle duration, can also improve the homogeneity of the final batch. In this framework, this study is focused on the investigation of the effects of the Vacuum Induced Nucleation control method (modified in a previous work)[1,2] on the final structure of the product. Two aspects will be taken into consideration: the uniformity among vials of the same batch (inter-vial) and the uniformity of the structure along the height of the product (intra-vial). It has to be pointed out that a non-uniform product structure can have an impact on the protein aggregation and redistribution, and cause a partial cake collapse or micro-collapse. This investigation is really useful to define some limits of the control method used in this work.

Effect of vacuum induced nucleation on the final product homogeneity / Oddone, I.; Van Bockstal, P. -J.; De Beer, T.; Barresi, A. A.; Pisano, R.. - STAMPA. - (2015), pp. 19-20. (Intervento presentato al convegno 7th International Conference on Lyophilization and Freeze-Drying tenutosi a Barcellona (Spain) nel 7-8 July 2015).

Effect of vacuum induced nucleation on the final product homogeneity

Oddone, I.;Barresi, A. A.;Pisano, R.
2015

Abstract

In the field of freeze drying of pharmaceutics the homogeneity of the sublimation flux during drying is fundamental to allow a final product with the same characteristics. Previous studies have shown that the control of freezing stage, in addition to a dramatic reduction of cycle duration, can also improve the homogeneity of the final batch. In this framework, this study is focused on the investigation of the effects of the Vacuum Induced Nucleation control method (modified in a previous work)[1,2] on the final structure of the product. Two aspects will be taken into consideration: the uniformity among vials of the same batch (inter-vial) and the uniformity of the structure along the height of the product (intra-vial). It has to be pointed out that a non-uniform product structure can have an impact on the protein aggregation and redistribution, and cause a partial cake collapse or micro-collapse. This investigation is really useful to define some limits of the control method used in this work.
File in questo prodotto:
File Dimensione Formato  
Irene_Oddone_Abstract_Barcelona_2015_Final.docx

non disponibili

Descrizione: abstract
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 849.5 kB
Formato Microsoft Word XML
849.5 kB Microsoft Word XML   Visualizza/Apri   Richiedi una copia
2015_ISL-FD_Barcelona_2015_Abstract.pdf

accesso aperto

Descrizione: Abstract
Tipologia: Abstract
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 403.44 kB
Formato Adobe PDF
403.44 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2615415