Static posturography provides an objective assessment of postural control by characterizing the body sway during upright standing. The Center-of-Pressure (CoP) signal is recorded by a force platform and it is analyzed by means of many different models and techniques. Most of the parameters calculated according to these different approaches are affected by relevant intra- and inter-subject variability and/or do not have a clear physiological interpretation. Traditional approaches decompose the CoP signal into antero-posterior and medio-lateral time series, corresponding to ankle plantar/dorsiflexion and hip adduction/abduction, respectively. In this study we hypothesized that CoP signals show inherent rotational characteristics. To verify our hypothesis we applied the rotary spectra analysis to the 2-dimensional CoP signal to decompose it into clockwise and counter-clockwise rotational components. We demonstrated the presence of rotational components in the CoP signal of healthy subjects, providing a reference data set of the spectral characteristics of these components.
Circular components in center of pressure signals / Agostini, Valentina; Chiaramello, Emma; Knaflitz, Marco. - In: MOTOR CONTROL. - ISSN 1087-1640. - STAMPA. - 17:(2013), pp. 355-369.
Circular components in center of pressure signals
AGOSTINI, VALENTINA;CHIARAMELLO, EMMA;KNAFLITZ, Marco
2013
Abstract
Static posturography provides an objective assessment of postural control by characterizing the body sway during upright standing. The Center-of-Pressure (CoP) signal is recorded by a force platform and it is analyzed by means of many different models and techniques. Most of the parameters calculated according to these different approaches are affected by relevant intra- and inter-subject variability and/or do not have a clear physiological interpretation. Traditional approaches decompose the CoP signal into antero-posterior and medio-lateral time series, corresponding to ankle plantar/dorsiflexion and hip adduction/abduction, respectively. In this study we hypothesized that CoP signals show inherent rotational characteristics. To verify our hypothesis we applied the rotary spectra analysis to the 2-dimensional CoP signal to decompose it into clockwise and counter-clockwise rotational components. We demonstrated the presence of rotational components in the CoP signal of healthy subjects, providing a reference data set of the spectral characteristics of these components.File | Dimensione | Formato | |
---|---|---|---|
AuthorsCopy.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
390.77 kB
Formato
Adobe PDF
|
390.77 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2507438
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo