The results of a measurement of the neutron emission from a Ti (metal)/D (gas) system by means of a spectrometer based on double scattering are reported. A approximately 2.5 sigma signal corresponding to an emission of (1.3 +/- 0.5) neutron s-1 g-1 has been observed.
Observation of 2.5 Mev Neutrons Emitted From A Titanium-deuterium System / T., Bressani; D., Calvo; A., Feliciello; C., Lamberti; Iazzi, Felice; Minetti, Bruno; R., Cherubini; A. M., I.; R. A., Ricci. - In: NUOVO CIMENTO DELLA SOCIETÀ ITALIANA DI FISICA. A, NUCLEI, PARTICLES AND FIELDS. - ISSN 1124-1861. - 104:9(1991), pp. 1413-1416. [10.1007/BF02789584]
Observation of 2.5 Mev Neutrons Emitted From A Titanium-deuterium System
IAZZI, Felice;MINETTI, Bruno;
1991
Abstract
The results of a measurement of the neutron emission from a Ti (metal)/D (gas) system by means of a spectrometer based on double scattering are reported. A approximately 2.5 sigma signal corresponding to an emission of (1.3 +/- 0.5) neutron s-1 g-1 has been observed.Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2500662
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo