In order to evaluate safety assessment of the Sanctuary of Vicoforte, Italy, a series of non-destructive tests were carried out for diagnostic inspection of its deterioration. Delamination of stone finishing and fresco painting were detected. Dynamic ambient vibration test was carried out and the relevant modes of vibration were identified resorting to the stochastic subspace identification method. The first two natural frequencies of the Sanctuary of Vicoforte were estimated to be about 1.93 Hz and 2.07 Hz in East-West and North-South directions, respectively. Therefore, the dome seems to be vulnerable to severe earthquake
Safety assessment of the Sanctuary of Vicoforte, Italy / Aoki, T.; Yuasa, N.; Hamasaki, H.; Nakano, Y.; Takahashi, N.; Tanigawa, Y.; Komiyama, T.; Ina, T.; Sabia, Donato; Demarie, GIACOMO VINCENZO. - In: INTERNATIONAL JOURNAL OF MATERIALS AND STRUCTURAL INTEGRITY. - ISSN 1745-0055. - ELETTRONICO. - 5:2/3(2011), pp. 215-240. [10.1504/IJMSI.2011.041935]
Safety assessment of the Sanctuary of Vicoforte, Italy
SABIA, Donato;DEMARIE, GIACOMO VINCENZO
2011
Abstract
In order to evaluate safety assessment of the Sanctuary of Vicoforte, Italy, a series of non-destructive tests were carried out for diagnostic inspection of its deterioration. Delamination of stone finishing and fresco painting were detected. Dynamic ambient vibration test was carried out and the relevant modes of vibration were identified resorting to the stochastic subspace identification method. The first two natural frequencies of the Sanctuary of Vicoforte were estimated to be about 1.93 Hz and 2.07 Hz in East-West and North-South directions, respectively. Therefore, the dome seems to be vulnerable to severe earthquakePubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2496058
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo