The fundamental passive mechanical properties of the bladder need to be known in order to design the most appropriate long-term surgical repair procedures and develop materials for bladder reconstruction. This study has focused on the bladder tissue viscoelastic behavior, providing a comprehensive analysis of the effects of fibers orientation, strain rate and loading history. Whole bladders harvested from one year old fat pigs (160 kg approximate weight) were dissected along the apex-to-base direction and samples were isolated from the lateral region of the wall, as well as along apex-to-base and transverse directions. Uniaxial monotonic (stress relaxation) and cyclic tests at different frequencies have been performed with the Bose Electroforce® 3200. Normalized stress relaxation functions have been interpolated using a second-order exponential series and loading and unloading stress–strain curves have been interpolated with a non-linear elastic model. The passive mechanical behavior of bladder tissue was shown to be heavily influenced by frequency and loading history, both in monotonic and cyclic tests. The anisotropy of the tissue was evident in monotonic and in cyclic tests as well, especially in tests performed on an exercised tissue and at high frequencies. In contrast, transverse and apex-to-base samples demonstrated an analogous relaxation behavior.
Bladder tissue passive response to monotonic and cyclic loading / Zanetti, Elisabetta; M., Perrini; Bignardi, Cristina; Audenino, Alberto. - In: BIORHEOLOGY. - ISSN 0006-355X. - STAMPA. - 49:1(2012), pp. 49-63. [10.3233/BIR-2012-0604]
Bladder tissue passive response to monotonic and cyclic loading
ZANETTI, ELISABETTA;BIGNARDI, CRISTINA;AUDENINO, Alberto
2012
Abstract
The fundamental passive mechanical properties of the bladder need to be known in order to design the most appropriate long-term surgical repair procedures and develop materials for bladder reconstruction. This study has focused on the bladder tissue viscoelastic behavior, providing a comprehensive analysis of the effects of fibers orientation, strain rate and loading history. Whole bladders harvested from one year old fat pigs (160 kg approximate weight) were dissected along the apex-to-base direction and samples were isolated from the lateral region of the wall, as well as along apex-to-base and transverse directions. Uniaxial monotonic (stress relaxation) and cyclic tests at different frequencies have been performed with the Bose Electroforce® 3200. Normalized stress relaxation functions have been interpolated using a second-order exponential series and loading and unloading stress–strain curves have been interpolated with a non-linear elastic model. The passive mechanical behavior of bladder tissue was shown to be heavily influenced by frequency and loading history, both in monotonic and cyclic tests. The anisotropy of the tissue was evident in monotonic and in cyclic tests as well, especially in tests performed on an exercised tissue and at high frequencies. In contrast, transverse and apex-to-base samples demonstrated an analogous relaxation behavior.File | Dimensione | Formato | |
---|---|---|---|
Zanetti et al Text Revised Edited_aPOST.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
497.69 kB
Formato
Adobe PDF
|
497.69 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/2495982
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo