The aim of this study was the optimization of cone calorimeter to determine the burning behavior of textile fabrics. In particular, the combustion behavior of commercial polyester textile fabrics with varying densities was studied in terms of time to ignition (TTI), heat release rate (HRR), and relative peak (pkHRR) were monitored. Reproducibility and repeatability of the data have been verified by the influence of instrument variable including incident heat flux, the temperature of ceramic backing pads and retaining grid used during sample mounting as well as sample weight (as the number of fabric layers), the density of textiles, and the relative humidity. A low reproducibility has been obtained when a wire grid was not used to stabilize samples during the tests. The effects of these variables on TTI and pkHRR were observed.

Optimization of the procedure to burn textile fabrics by cone calorimeter: part I. Combustion behavior of polyester / Tata, JENNIFER KATTY; Alongi, Jenny; Carosio, Federico; Frache, Alberto. - In: FIRE AND MATERIALS. - ISSN 0308-0501. - STAMPA. - 35:(2011), pp. 397-409. [10.1002/fam.1061]

Optimization of the procedure to burn textile fabrics by cone calorimeter: part I. Combustion behavior of polyester

TATA, JENNIFER KATTY;ALONGI, JENNY;CAROSIO, FEDERICO;FRACHE, ALBERTO
2011

Abstract

The aim of this study was the optimization of cone calorimeter to determine the burning behavior of textile fabrics. In particular, the combustion behavior of commercial polyester textile fabrics with varying densities was studied in terms of time to ignition (TTI), heat release rate (HRR), and relative peak (pkHRR) were monitored. Reproducibility and repeatability of the data have been verified by the influence of instrument variable including incident heat flux, the temperature of ceramic backing pads and retaining grid used during sample mounting as well as sample weight (as the number of fabric layers), the density of textiles, and the relative humidity. A low reproducibility has been obtained when a wire grid was not used to stabilize samples during the tests. The effects of these variables on TTI and pkHRR were observed.
2011
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2440882
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo