Heat transfer to supercritical pressure water is analyzed with reference to the thermal-hydraulics of boiler plants. The mechanisms of the heat transfer deterioration, concerning the maximum allowable wall temperature, are particularly investigated. The most widely accepted heat transfer correlations are compared with B&W test data and with some measurements performed by ENEL at a supercritical 660 MWe steam generator.

Deteriorated Heat Transfer at Supercritical Pressure = Fenomeni di deterioramento nello scambio termico a pressione ipercritica / Malandrone, Mario; Panella, Bruno; Pedrelli, G; Sobrero, G.. - In: L'ENERGIA ELETTRICA. - ISSN 1590-7651. - 64:2(1987), pp. 45-56.

Deteriorated Heat Transfer at Supercritical Pressure = Fenomeni di deterioramento nello scambio termico a pressione ipercritica

MALANDRONE, Mario;PANELLA, BRUNO;
1987

Abstract

Heat transfer to supercritical pressure water is analyzed with reference to the thermal-hydraulics of boiler plants. The mechanisms of the heat transfer deterioration, concerning the maximum allowable wall temperature, are particularly investigated. The most widely accepted heat transfer correlations are compared with B&W test data and with some measurements performed by ENEL at a supercritical 660 MWe steam generator.