Aim: To evaluate the influence of immersion in NaOCl on resistance to cyclic fatigue fracture and corrosion of ProTaper NiTi Rotary instruments. Methodology: A total of 120 new ProTaper NiTi Rotary files (F2) were randomized and assigned to three different groups of 40 each. Group 1 was the control group; 20 mm (excluding the shaft) of group 2 instruments were immersed in 5% NaOCl at 50°C for 5 min; instruments in group 3 were completely immersed in 5% NaOCl at 50°C for 5 min. All instruments were then tested for cyclic fatigue, recording the time in seconds to fracture. Data were analysed by the Kruskall-Wallis test and post-hoc multiple comparisons (P < 0.05). Micromorphological and microchemical analyses were also completed by means of a field emission scanning electron microscopy (SEM) on those instruments in group 3 that had undergone early fracture. Results: Instruments in group 3 had a significantly lower resistance to fracture because of cyclic fatigue than those in groups 1 and 2 (P < 0.001). In some instruments in group 3, early fracture occurred after only a few seconds of fatigue testing. SEM observations revealed evident signs of corrosion of the fractured instruments. Conclusion: Group 3 had significantly reduced resistance to cyclic fatigue compared with instruments in groups 1 and 2. The phenomenon of early fracture may be attributed to galvanic corrosion induced by the presence of dissimilar metals, where one acts as the cathode of a galvanic couple, established when the instrument is immersed in NaOCl solution. The NiTi alloy may acts as the anode and thus undergoes corrosion.

Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments / E., Berutti; Angelini, EMMA PAOLA MARIA VIRGINIA; M., Rigolone; G., MIGLIARETTI G; D., Pasqualini. - In: INTERNATIONAL ENDODONTIC JOURNAL. - ISSN 0143-2885. - STAMPA. - 39:9(2006), pp. 693-699. [10.1111/j.1365-2591.2006.01134.x]

Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments

ANGELINI, EMMA PAOLA MARIA VIRGINIA;
2006

Abstract

Aim: To evaluate the influence of immersion in NaOCl on resistance to cyclic fatigue fracture and corrosion of ProTaper NiTi Rotary instruments. Methodology: A total of 120 new ProTaper NiTi Rotary files (F2) were randomized and assigned to three different groups of 40 each. Group 1 was the control group; 20 mm (excluding the shaft) of group 2 instruments were immersed in 5% NaOCl at 50°C for 5 min; instruments in group 3 were completely immersed in 5% NaOCl at 50°C for 5 min. All instruments were then tested for cyclic fatigue, recording the time in seconds to fracture. Data were analysed by the Kruskall-Wallis test and post-hoc multiple comparisons (P < 0.05). Micromorphological and microchemical analyses were also completed by means of a field emission scanning electron microscopy (SEM) on those instruments in group 3 that had undergone early fracture. Results: Instruments in group 3 had a significantly lower resistance to fracture because of cyclic fatigue than those in groups 1 and 2 (P < 0.001). In some instruments in group 3, early fracture occurred after only a few seconds of fatigue testing. SEM observations revealed evident signs of corrosion of the fractured instruments. Conclusion: Group 3 had significantly reduced resistance to cyclic fatigue compared with instruments in groups 1 and 2. The phenomenon of early fracture may be attributed to galvanic corrosion induced by the presence of dissimilar metals, where one acts as the cathode of a galvanic couple, established when the instrument is immersed in NaOCl solution. The NiTi alloy may acts as the anode and thus undergoes corrosion.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1647358
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo