In order to predict conducted electromagnetic interference in inverter-motor drive systems, high-frequency (HF) motor models are requested and the involved parameters have to be available. In previous studies, the authors have presented an accurate HF model for induction motors and they have defined the procedures to identify the model parameters. In this paper, these results are extended to several types and sizes of industrial ac motors such as induction, synchronous reluctance (without interior permanent magnets), and brushless motors. The model parameter-identification procedure has been improved, and it is based on a least-squares data fitting applied to the measured magnitude and phase-frequency-response curves of the phase-to-ground and the phase-to-neutral impedances. The aim of this paper is to provide quick indications to select the suitable values of the HF model parameters, with reference to the size and type of the ac motor, to evaluate the HF voltage and current components in inverted-fed ac motor systems.

Experimental High-Frequency Parameter Identification of AC Electrical Motors / Boglietti, Aldo; Cavagnino, Andrea; Lazzari, Mario. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 43:1(2007), pp. 23-29. [10.1109/TIA.2006.887313]

Experimental High-Frequency Parameter Identification of AC Electrical Motors

BOGLIETTI, Aldo;CAVAGNINO, ANDREA;LAZZARI, MARIO
2007

Abstract

In order to predict conducted electromagnetic interference in inverter-motor drive systems, high-frequency (HF) motor models are requested and the involved parameters have to be available. In previous studies, the authors have presented an accurate HF model for induction motors and they have defined the procedures to identify the model parameters. In this paper, these results are extended to several types and sizes of industrial ac motors such as induction, synchronous reluctance (without interior permanent magnets), and brushless motors. The model parameter-identification procedure has been improved, and it is based on a least-squares data fitting applied to the measured magnitude and phase-frequency-response curves of the phase-to-ground and the phase-to-neutral impedances. The aim of this paper is to provide quick indications to select the suitable values of the HF model parameters, with reference to the size and type of the ac motor, to evaluate the HF voltage and current components in inverted-fed ac motor systems.
File in questo prodotto:
File Dimensione Formato  
1507150.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Pubblico - Tutti i diritti riservati
Dimensione 391.88 kB
Formato Adobe PDF
391.88 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1507150
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo