Ultrasonic tomography on standing trees. Ultrasonic tomography was used for the detection of degradation of transversal section of a beech, attacked by white decay. The image reconstruction of the transversal section of the tree in 2D was obtained with a software, which used the values of ultrasonic velocities measured at different heights from the ground. The attacked wood is characterised by low velocities. The measurements were performed with special transducers of 1 MHz, without damaging the bark of the tree. To improve the readings of the signals, a frequency analysis was performed. The ultrasonic tomographies were compared with the corresponding photographic images and with data obtained with a “Resistograph”. A good agreement between ultrasonic tomographies and photographs was observed. The image resolution is between 4 and 5 cm. Presently, this is the best resolution ever obtained with an acoustic nondestructive method on a standing tree.

Tomographie ultrasonore pour les arbres sur pied / Martinis, R.; Socco, Laura; Sambuelli, Luigi; Nicolotti, G.; Schmitt, O.; Bucur, V.. - In: ANNALS OF FOREST SCIENCE. - ISSN 1286-4560. - ELETTRONICO. - 61:2(2004), pp. 157-162. [10.1051/forest:2004007]

Tomographie ultrasonore pour les arbres sur pied

SOCCO, LAURA;SAMBUELLI, Luigi;
2004

Abstract

Ultrasonic tomography on standing trees. Ultrasonic tomography was used for the detection of degradation of transversal section of a beech, attacked by white decay. The image reconstruction of the transversal section of the tree in 2D was obtained with a software, which used the values of ultrasonic velocities measured at different heights from the ground. The attacked wood is characterised by low velocities. The measurements were performed with special transducers of 1 MHz, without damaging the bark of the tree. To improve the readings of the signals, a frequency analysis was performed. The ultrasonic tomographies were compared with the corresponding photographic images and with data obtained with a “Resistograph”. A good agreement between ultrasonic tomographies and photographs was observed. The image resolution is between 4 and 5 cm. Presently, this is the best resolution ever obtained with an acoustic nondestructive method on a standing tree.
File in questo prodotto:
File Dimensione Formato  
12800_UPLOAD.pdf

accesso aperto

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 847.52 kB
Formato Adobe PDF
847.52 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1405515