This paper deals with the role of the radiation thermal resistances in industrial motors and describes a test set useful for the resistance evaluation. The test set is based on a vacuum chamber and on a numerical acquisition system, and the resistances are obtained by monitoring motor temperatures during a heating test. An analytical model that describes how the radiation resistance depends on the motor temperature is also provided. Experimental results obtained on a totally enclosed fan-cooled 150-W induction motor are shown and discussed.
Evaluation of Radiation Thermal Resistances in Industrial Motors / Boglietti, Aldo; Cavagnino, Andrea; Parvis, Marco; Vallan, Alberto. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - STAMPA. - 42:3(2006), pp. 688-693. [10.1109/TIA.2006.873655]
Evaluation of Radiation Thermal Resistances in Industrial Motors
BOGLIETTI, Aldo;CAVAGNINO, ANDREA;PARVIS, Marco;VALLAN, Alberto
2006
Abstract
This paper deals with the role of the radiation thermal resistances in industrial motors and describes a test set useful for the resistance evaluation. The test set is based on a vacuum chamber and on a numerical acquisition system, and the resistances are obtained by monitoring motor temperatures during a heating test. An analytical model that describes how the radiation resistance depends on the motor temperature is also provided. Experimental results obtained on a totally enclosed fan-cooled 150-W induction motor are shown and discussed.File | Dimensione | Formato | |
---|---|---|---|
2006-TronIM-Evaluation of radiation thermal resistances in industrial motors.pdf
accesso aperto
Tipologia:
2. Post-print / Author's Accepted Manuscript
Licenza:
Pubblico - Tutti i diritti riservati
Dimensione
418.67 kB
Formato
Adobe PDF
|
418.67 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
https://hdl.handle.net/11583/1399231
Attenzione
Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo