The issue of improving the building energy efficiency led to the development of calculation methods for the building energy performance assessment. To overcome the low accessibility to detailed input data, the recently introduced EN ISO 52016-1 hourly method is based on assumptions and simplifications chosen to allow a sufficient accuracy in the outcomes with a low amount of input data. Among these assumptions, a simplified mass distribution in the envelope components is considered. In the present work, the hypothesis of the simplified heat conduction model introduced by the EN ISO 52016-1 technical standard and an improved solution provided by its Italian National Annex were evaluated. In particular, the accuracy in the prediction of the internal surface temperature was assessed in comparison with a detailed finite difference conduction algorithm. The validation was performed for 5 opaque component test cases, covering a wide range of areal heat capacity values, by considering both internal and external thermal constraints (e.g. variation of the air temperature). For the structures and boundary conditions considered, results reveal that the standard algorithm allows to predict the internal surface temperatures with a valuable level of accuracy compared to the finite difference algorithm.

Validation of the simplified heat conduction model of EN ISO 52016-1 / De Luca, Giovanna; Ballarini, Ilaria; Bianco Mauthe Degerfeld, Franz Giorgio Maria; Corrado, Vincenzo. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - ELETTRONICO. - 2069:(2021), pp. 1-8. (Intervento presentato al convegno 8th International Building Physics Conference (IBPC 2021) tenutosi a Copenhagen nel 25-27 August 2021) [10.1088/1742-6596/2069/1/012136].

Validation of the simplified heat conduction model of EN ISO 52016-1

De Luca, Giovanna;Ballarini, Ilaria;Bianco Mauthe Degerfeld, Franz Giorgio Maria;Corrado, Vincenzo
2021

Abstract

The issue of improving the building energy efficiency led to the development of calculation methods for the building energy performance assessment. To overcome the low accessibility to detailed input data, the recently introduced EN ISO 52016-1 hourly method is based on assumptions and simplifications chosen to allow a sufficient accuracy in the outcomes with a low amount of input data. Among these assumptions, a simplified mass distribution in the envelope components is considered. In the present work, the hypothesis of the simplified heat conduction model introduced by the EN ISO 52016-1 technical standard and an improved solution provided by its Italian National Annex were evaluated. In particular, the accuracy in the prediction of the internal surface temperature was assessed in comparison with a detailed finite difference conduction algorithm. The validation was performed for 5 opaque component test cases, covering a wide range of areal heat capacity values, by considering both internal and external thermal constraints (e.g. variation of the air temperature). For the structures and boundary conditions considered, results reveal that the standard algorithm allows to predict the internal surface temperatures with a valuable level of accuracy compared to the finite difference algorithm.
File in questo prodotto:
File Dimensione Formato  
De_Luca_2021_J._Phys.__Conf._Ser._2069_012136.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2947847