PMSMs are widely used in applications on electric vehicles, robotics and mechatronic systems of industrial machinery. Thus it becomes increasingly interesting to prevent their fault or malfunctioning with Predictive Maintenance (PdM). However, reaching this outcome could be difficult, especially if the stationary condition is not achieved and without additional sensors. This paper examines the use of a load torque observer based on Extended Kalman Filter for the diagnosis of electric drives working under non-stationary conditions. The proposed Motor Torque Analysis (MTA) is compared with the Motor Current Signature Analysis by evaluating their diagnostic capabilities under the assumed conditions. Finally, the results of bearing failure detection under non-stationary conditions are presented, highlighting the superior diagnostic capabilities of the MTA under such conditions.

Comparison of PMSMs Motor Current Signature Analysis and Motor Torque Analysis Under Transient Conditions / Bonci, Andrea; Indri, Marina; Kermenov, Renat; Longhi, Sauro; Nabissi, Giacomo. - ELETTRONICO. - (2021), pp. 1-6. (Intervento presentato al convegno 2021 IEEE 19th International Conference on Industrial Informatics (INDIN 2021) tenutosi a Palma de Mallorca, Spain nel 21-23 July 2021) [10.1109/INDIN45523.2021.9557553].

Comparison of PMSMs Motor Current Signature Analysis and Motor Torque Analysis Under Transient Conditions

Indri, Marina;
2021

Abstract

PMSMs are widely used in applications on electric vehicles, robotics and mechatronic systems of industrial machinery. Thus it becomes increasingly interesting to prevent their fault or malfunctioning with Predictive Maintenance (PdM). However, reaching this outcome could be difficult, especially if the stationary condition is not achieved and without additional sensors. This paper examines the use of a load torque observer based on Extended Kalman Filter for the diagnosis of electric drives working under non-stationary conditions. The proposed Motor Torque Analysis (MTA) is compared with the Motor Current Signature Analysis by evaluating their diagnostic capabilities under the assumed conditions. Finally, the results of bearing failure detection under non-stationary conditions are presented, highlighting the superior diagnostic capabilities of the MTA under such conditions.
2021
978-1-7281-4395-8
File in questo prodotto:
File Dimensione Formato  
INDIN2021.pdf

non disponibili

Descrizione: Versione a stampa
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 8.04 MB
Formato Adobe PDF
8.04 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
INDIN2021_authors_version.pdf

accesso aperto

Descrizione: Versione accettata
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 3.67 MB
Formato Adobe PDF
3.67 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2946152