The impact of spread-spectrum techniques used to mitigate EMI from power converters on Power Line Communication (PLC) systems is studied in this paper. A buck converter, utilizing a Random Carrier Frequency Modulation with Fixed Duty cycle (RCFMFD) based control is considered as a source of conducted EMI and a narrowband G3-PLC as the victim. It is shown that, although considered to be an EMI mitigating technique, the spread spectrum technique has a detrimental effect on the communication channel, which can be explained in the framework of Shannon’s information theory. Conventional emission evaluation methods are therefore incompatible with modern day’s technology.

Electromagnetic Interference of Spread-Spectrum Modulated Power Converters in G3-PLC Power Line Communication Systems / El Sayed, Waseem; Crovetti, PAOLO STEFANO; Moonen, Niek; Lezynski, Piotr; Smolenski, Robert; Leferink, Frank. - In: IEEE LETTERS ON ELECTROMAGNETIC COMPATIBILITY PRACTICE AND APPLICATIONS. - ISSN 2637-6423. - STAMPA. - 3:4(2021), pp. 118-122. [10.1109/LEMCPA.2021.3121091]

Electromagnetic Interference of Spread-Spectrum Modulated Power Converters in G3-PLC Power Line Communication Systems

Paolo Crovetti;
2021

Abstract

The impact of spread-spectrum techniques used to mitigate EMI from power converters on Power Line Communication (PLC) systems is studied in this paper. A buck converter, utilizing a Random Carrier Frequency Modulation with Fixed Duty cycle (RCFMFD) based control is considered as a source of conducted EMI and a narrowband G3-PLC as the victim. It is shown that, although considered to be an EMI mitigating technique, the spread spectrum technique has a detrimental effect on the communication channel, which can be explained in the framework of Shannon’s information theory. Conventional emission evaluation methods are therefore incompatible with modern day’s technology.
File in questo prodotto:
File Dimensione Formato  
2021-10-11_Rev13_L_EMC_PA.pdf

accesso aperto

Descrizione: Post-print non editoriale
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.04 MB
Formato Adobe PDF
1.04 MB Adobe PDF Visualizza/Apri
Crovetti-ElectromagneticInterference.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.35 MB
Formato Adobe PDF
2.35 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2934092