The ability to monitor the junction temperature of power devices during the operation of a power converter will be the key enabler towards combined higher performance and higher reliability of power electronics. Starting from the well-known dependency of the RON with the junction temperature of SiC power MOSFETs, an innovative solution is proposed to obtain the high-dynamic estimation of the junction temperature of all the power devices. This work focuses on the commissioning stage of a three-phase, 2-level voltage source inverter, enabling the real-time temperature feedback of all six power devices of the bridge during operation. A selection of experimental results is reported.

Three-phase Inverter for Formula SAE Electric with Online Junction Temperature Estimation of all SiC MOSFETs / Stella, F.; Pellegrino, G.; Armando, E.. - ELETTRONICO. - 2020-:(2020), pp. 1154-1161. (Intervento presentato al convegno 35th Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2020 tenutosi a USA nel 2020) [10.1109/APEC39645.2020.9124302].

Three-phase Inverter for Formula SAE Electric with Online Junction Temperature Estimation of all SiC MOSFETs

Stella F.;Pellegrino G.;Armando E.
2020

Abstract

The ability to monitor the junction temperature of power devices during the operation of a power converter will be the key enabler towards combined higher performance and higher reliability of power electronics. Starting from the well-known dependency of the RON with the junction temperature of SiC power MOSFETs, an innovative solution is proposed to obtain the high-dynamic estimation of the junction temperature of all the power devices. This work focuses on the commissioning stage of a three-phase, 2-level voltage source inverter, enabling the real-time temperature feedback of all six power devices of the bridge during operation. A selection of experimental results is reported.
2020
978-1-7281-4829-8
File in questo prodotto:
File Dimensione Formato  
Three-phase Inverter for Formula SAE Electric with Online Junction Temperature Estimation of all SiC MOSFETs.pdf

accesso aperto

Descrizione: Three-phase Inverter for Formula SAE Electric with Online Junction Temperature Estimation of all SiC MOSFETs
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.41 MB
Formato Adobe PDF
1.41 MB Adobe PDF Visualizza/Apri
09124302.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.76 MB
Formato Adobe PDF
2.76 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2853261