In this work, the characteristics of X-ray beam generated from a plasma produced by focusing a Nd-Yag/glass laser beam on mylar or yttrium target were presented. For each target material, the conversion efficiencies of the soft X-ray emission in two different energy ranges, (i) 300-510 eV (almost coincident with the Water Window), (ii) 450-850 eV were measured. The experimental results of the conversion efficiencies will be utilized at the PLASMA-X laboratory of L'Aquila University for the realization of an intense monochromatic X-ray microbeam to be used in radiobiological and in transmission X-ray microscopy applications. In the presented experimental set-up, at the wavelength of 2.48 nm, a monochromatic soft X-rays beam was collected by multilayer spherical mirrors reflecting at an incidence angle close to the normal of the surface. The optical system geometry, the monochromatic beam intensity and the measures of efficiency of conversion of X-ray were described in this paper [5]. © 2012 Elsevier B.V.

X-ray emission analysis of a plasma source using an yttrium and a mylar target for the generation of 2.48 nm wavelength microbeam / Palladino, L.; Lorenzo, R. G. D.; Emilio, M. D. P.; Limongi, T.. - In: APPLIED SURFACE SCIENCE. - ISSN 0169-4332. - STAMPA. - 272:(2013), pp. 119-123. [10.1016/j.apsusc.2012.09.097]

X-ray emission analysis of a plasma source using an yttrium and a mylar target for the generation of 2.48 nm wavelength microbeam

Limongi T.
2013

Abstract

In this work, the characteristics of X-ray beam generated from a plasma produced by focusing a Nd-Yag/glass laser beam on mylar or yttrium target were presented. For each target material, the conversion efficiencies of the soft X-ray emission in two different energy ranges, (i) 300-510 eV (almost coincident with the Water Window), (ii) 450-850 eV were measured. The experimental results of the conversion efficiencies will be utilized at the PLASMA-X laboratory of L'Aquila University for the realization of an intense monochromatic X-ray microbeam to be used in radiobiological and in transmission X-ray microscopy applications. In the presented experimental set-up, at the wavelength of 2.48 nm, a monochromatic soft X-rays beam was collected by multilayer spherical mirrors reflecting at an incidence angle close to the normal of the surface. The optical system geometry, the monochromatic beam intensity and the measures of efficiency of conversion of X-ray were described in this paper [5]. © 2012 Elsevier B.V.
File in questo prodotto:
File Dimensione Formato  
Palladino_Applied Surface Science_2013.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 489.18 kB
Formato Adobe PDF
489.18 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2852792