Purpose: The evaluation of a mini or simulated fluid challenge is still a complex and open issue in the clinical setting and it is of paramount significance for the fluid therapy optimization. We here investigated the capacity of a new hemodynamic parameter, the venous Pulse Wave Velocity (vPWV), to detect the effect of passive leg raising (PLR). Materials and methods: In 15 healthy volunteers (7 M, 8 F, age 26 ± 3) venous pressure pulses were elicited by pneumatic compressions of the left hand and proximally detected by ultrasound for calculation of the vPWV. We also non-invasively measured the basilic vein (BV) cross-sectional perimeter, and peripheral venous pressure (PVP). The PLR manoeuvre was performed twice to evaluate reliability of the assessment. Results: The PLR had an overall statistically significant effect on the entire set of variables (MANOVA, p < 0.05): vPWV increased from 2.11 ± 0.46 to 2.30 ± 0.47 m/s (p = 0.01; average increase: 10%). This effect was transient and dropped below 5% after about 3 min. A significant increase was also exhibited by BV size and PVP. In consecutive measurements vPWV showed little intra-subject variability (CoV = 8%) and good reliability (ICC = 0.87). Finally, the vPWV responses to the two PLRs exhibited good agreement (paired T-test: p = 0.96), and moderate reliability (ICC = 0.57). Conclusion: These results demonstrated that vPWV can be non-invasively, objectively and reliably measured in healthy subjects and that it is adequate to detect small pressure/volume variations, as induced by PLR-from-supine. These characteristics make it suitable for clinical applications.

Venous Pulse Wave Velocity variation in response to a simulated fluid challenge in healthy subjects / Ermini, L.; Chiarello, N. E.; De Benedictis, C.; Ferraresi, C.; Roatta, S.. - In: BIOMEDICAL SIGNAL PROCESSING AND CONTROL. - ISSN 1746-8094. - ELETTRONICO. - 63:(2021), pp. 1-7. [10.1016/j.bspc.2020.102177]

Venous Pulse Wave Velocity variation in response to a simulated fluid challenge in healthy subjects

De Benedictis C.;Ferraresi C.;
2021

Abstract

Purpose: The evaluation of a mini or simulated fluid challenge is still a complex and open issue in the clinical setting and it is of paramount significance for the fluid therapy optimization. We here investigated the capacity of a new hemodynamic parameter, the venous Pulse Wave Velocity (vPWV), to detect the effect of passive leg raising (PLR). Materials and methods: In 15 healthy volunteers (7 M, 8 F, age 26 ± 3) venous pressure pulses were elicited by pneumatic compressions of the left hand and proximally detected by ultrasound for calculation of the vPWV. We also non-invasively measured the basilic vein (BV) cross-sectional perimeter, and peripheral venous pressure (PVP). The PLR manoeuvre was performed twice to evaluate reliability of the assessment. Results: The PLR had an overall statistically significant effect on the entire set of variables (MANOVA, p < 0.05): vPWV increased from 2.11 ± 0.46 to 2.30 ± 0.47 m/s (p = 0.01; average increase: 10%). This effect was transient and dropped below 5% after about 3 min. A significant increase was also exhibited by BV size and PVP. In consecutive measurements vPWV showed little intra-subject variability (CoV = 8%) and good reliability (ICC = 0.87). Finally, the vPWV responses to the two PLRs exhibited good agreement (paired T-test: p = 0.96), and moderate reliability (ICC = 0.57). Conclusion: These results demonstrated that vPWV can be non-invasively, objectively and reliably measured in healthy subjects and that it is adequate to detect small pressure/volume variations, as induced by PLR-from-supine. These characteristics make it suitable for clinical applications.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1746809420303165-main.pdf

non disponibili

Descrizione: Publisher post-print
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 2.21 MB
Formato Adobe PDF
2.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
BSPC-S-20-00492_ridotto.pdf

Open Access dal 03/09/2022

Descrizione: Author post-print
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: Creative commons
Dimensione 805.92 kB
Formato Adobe PDF
805.92 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2845964