The paper deals with the corrosion resistance in chloride solutions of an AlSi10Mg alloy obtained by laser powder bed fusion (LPBF) process. The potentiodynamic tests were carried out in solutions having different chloride contents. The results emphasize the role of chloride concentration on localized corrosion. The increase of concentration reduces pitting potential. In addition, the influence of the post-processing heat treatment temperature was recognized. Penetrating attacks occurred either on after low temperatures stress relieving or specimens without any treatment, promoted by selective dissolution of the α-Al phase stimulated by galvanic coupling with noble silicon precipitates at the border of the melt pool. Such penetrating morphology was not observed after heat treatments at high temperature.

Corrosion resistance in chloride solution of the AlSi10Mg alloy obtained by means of LPBF / Cabrini, M.; Lorenzi, S.; Pastore, T.; Testa, C.; Manfredi, D.; Cattano, G.; Calignano, F.. - In: SURFACE AND INTERFACE ANALYSIS. - ISSN 0142-2421. - 51:12(2019), pp. 1159-1164. [10.1002/sia.6601]

Corrosion resistance in chloride solution of the AlSi10Mg alloy obtained by means of LPBF

Cabrini M.;Manfredi D.;Cattano G.;Calignano F.
2019

Abstract

The paper deals with the corrosion resistance in chloride solutions of an AlSi10Mg alloy obtained by laser powder bed fusion (LPBF) process. The potentiodynamic tests were carried out in solutions having different chloride contents. The results emphasize the role of chloride concentration on localized corrosion. The increase of concentration reduces pitting potential. In addition, the influence of the post-processing heat treatment temperature was recognized. Penetrating attacks occurred either on after low temperatures stress relieving or specimens without any treatment, promoted by selective dissolution of the α-Al phase stimulated by galvanic coupling with noble silicon precipitates at the border of the melt pool. Such penetrating morphology was not observed after heat treatments at high temperature.
File in questo prodotto:
File Dimensione Formato  
sia.6601.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 835.61 kB
Formato Adobe PDF
835.61 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
SIA-18-0325.pdf

Open Access dal 22/12/2019

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 277.41 kB
Formato Adobe PDF
277.41 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2827848