Some aspects related to the 3-D base isolation of structures are presented in this paper through a numerical approach. A traditional horizontal base isolation system with the use of high damping rubber bearings (HDRB) is coupled with a tuned mass damper (TMD) in the vertical direction. Both lightweight (e.g. artworks or special equipment) and massive structures (a nuclear power plant building) have been considered and possible positive and negative aspects from the implementation of the proposed hybrid control strategy are investigated. It is found that the TMD is able to provide a reliable source of energy dissipation, and to control the vertical motion of the structure, only when this has a low value of damping. For damping values that approximately exceed the 5% limit, the positive effects of TMD are negligible, if not worsening.

Some aspects on 3D base isolation of heavy and lightweight structures with TMD / Domaneschi, M.; Martinelli, L.; Cimellaro, G. P.. - STAMPA. - 1:(2019), pp. 2034-2045. (Intervento presentato al convegno 7th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, COMPDYN 2019 tenutosi a Crete (Greece) nel 24 June 2019 through 26 June 2019) [10.7712/120119.7056.19945].

Some aspects on 3D base isolation of heavy and lightweight structures with TMD

Domaneschi M.;Cimellaro G. P.
2019

Abstract

Some aspects related to the 3-D base isolation of structures are presented in this paper through a numerical approach. A traditional horizontal base isolation system with the use of high damping rubber bearings (HDRB) is coupled with a tuned mass damper (TMD) in the vertical direction. Both lightweight (e.g. artworks or special equipment) and massive structures (a nuclear power plant building) have been considered and possible positive and negative aspects from the implementation of the proposed hybrid control strategy are investigated. It is found that the TMD is able to provide a reliable source of energy dissipation, and to control the vertical motion of the structure, only when this has a low value of damping. For damping values that approximately exceed the 5% limit, the positive effects of TMD are negligible, if not worsening.
File in questo prodotto:
File Dimensione Formato  
190422_COMPDYN_2019_Isol_NPP_Statue.pdf

accesso aperto

Descrizione: Accepted manuscript
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2818052