Interstitial condensation and water accumulation risk in building envelopes could be assessed with methods and models based on moisture migration through porous media coupled to heat transfer. One of the difficulties in evaluating the boundary conditions for the heat and mass transfer model is the choice of an appropriate weather file. The most advanced models, described by the standard EN 15026:2007, require the hourly values of rain, wind, radiation, temperature and relative humidity to compute the water content in the porous materials. In this contribution, the method described by the standard EN ISO 15927-4:2005, typically used to design Moisture Reference Years (MRY), has been extended to the design of 34 typologies of representative weather files. The generation criteria have been based on the assumption that the simulation results are influenced by rain deposition on the considered wall. The procedure has been followed considering 5 different wall exposures that lead to different MRY. The years of the climate of Turin (Italy) between 2002 and 2016 have been considered for the generation of the reference years. Finally, the annual mean moisture contents for two common wall types have been calculated using the obtained MRY and compared to the annual mean moisture contents obtained with the measured weather data, and the effects of the selection of the weather parameters is presented.

Hygrothermal modelling of building enclosures: reference year design for moisture accumulation and condensation risk assessment / Libralato, Michele; Murano, Giovanni; Saro, Onorio; DE ANGELIS, Alessandra; Corrado, Vincenzo. - ELETTRONICO. - (2018), pp. 1395-1400. (Intervento presentato al convegno 7th International Building Physics Conference (IBPC 2018) tenutosi a Syracuse nel September 23-26, 2018) [10.14305/ibpc.2018.ps19].

Hygrothermal modelling of building enclosures: reference year design for moisture accumulation and condensation risk assessment

MURANO, GIOVANNI;CORRADO, VINCENZO
2018

Abstract

Interstitial condensation and water accumulation risk in building envelopes could be assessed with methods and models based on moisture migration through porous media coupled to heat transfer. One of the difficulties in evaluating the boundary conditions for the heat and mass transfer model is the choice of an appropriate weather file. The most advanced models, described by the standard EN 15026:2007, require the hourly values of rain, wind, radiation, temperature and relative humidity to compute the water content in the porous materials. In this contribution, the method described by the standard EN ISO 15927-4:2005, typically used to design Moisture Reference Years (MRY), has been extended to the design of 34 typologies of representative weather files. The generation criteria have been based on the assumption that the simulation results are influenced by rain deposition on the considered wall. The procedure has been followed considering 5 different wall exposures that lead to different MRY. The years of the climate of Turin (Italy) between 2002 and 2016 have been considered for the generation of the reference years. Finally, the annual mean moisture contents for two common wall types have been calculated using the obtained MRY and compared to the annual mean moisture contents obtained with the measured weather data, and the effects of the selection of the weather parameters is presented.
File in questo prodotto:
File Dimensione Formato  
Libralato et al._IBPC 2018_p.1394-1400.pdf

accesso aperto

Descrizione: Libralato et al._IBPC 2018_p.1394-1400
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Creative commons
Dimensione 847.93 kB
Formato Adobe PDF
847.93 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2810917