The paper illustrates the development and the application of an active monitoring system, and analyzes the investigated dynamic behaviour of the structure where the system is applied. The system is installed on a 250 m suspended arch steel bridge that has been instrumented with sensors of different type. This work focuses on the employed methodologies and obtained results related to the dynamic monitoring of the bridge. The use of the Operational Modal Analysis techniques with data-driven stochastic subspace identification algorithms allows the extraction of the structural dynamic characteristics: natural frequencies, damping ratios, and mode shapes. These data are in overall accordance with those calculated through the computational model utilized by the active monitoring system. Besides, the definition of a range of scattering of modal parameters, under specific conditions, has been obtained. The bridge has very low vibration frequencies, below 1 Hz for all significant modes. The outcomes indicate that the estimation of dynamic characteristics and the corresponding accuracy is influenced by several factors, including the length of the accelerometric acquisitions and the followed specific procedures. The impact of environmental factors, with particular reference to the temperature, is examined. Compared to the damping ratio, the natural frequency shows higher estimation accuracy and marked sensitivity to the environmental factor. Consequently, in the selection of benchmark for damage detection, it should be taken into account that the two modal parameters have specific criticalities. Once that the modal parameter has been chosen, values outside the estimated uncertainty range can be considered as alarm triggers.

Customised active monitoring system for structural control and maintenance optimisation / Chiaia, Bernardino; Marasco, Giulia; Ventura, Giulio; ZANNINI QUIRINI, Cristina. - In: JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING. - ISSN 2190-5452. - 10:(2020), pp. 267-282. [10.1007/s13349-020-00382-8]

Customised active monitoring system for structural control and maintenance optimisation

Bernardino Chiaia;Giulia Marasco;Giulio Ventura;Cristina Zannini Quirini
2020

Abstract

The paper illustrates the development and the application of an active monitoring system, and analyzes the investigated dynamic behaviour of the structure where the system is applied. The system is installed on a 250 m suspended arch steel bridge that has been instrumented with sensors of different type. This work focuses on the employed methodologies and obtained results related to the dynamic monitoring of the bridge. The use of the Operational Modal Analysis techniques with data-driven stochastic subspace identification algorithms allows the extraction of the structural dynamic characteristics: natural frequencies, damping ratios, and mode shapes. These data are in overall accordance with those calculated through the computational model utilized by the active monitoring system. Besides, the definition of a range of scattering of modal parameters, under specific conditions, has been obtained. The bridge has very low vibration frequencies, below 1 Hz for all significant modes. The outcomes indicate that the estimation of dynamic characteristics and the corresponding accuracy is influenced by several factors, including the length of the accelerometric acquisitions and the followed specific procedures. The impact of environmental factors, with particular reference to the temperature, is examined. Compared to the damping ratio, the natural frequency shows higher estimation accuracy and marked sensitivity to the environmental factor. Consequently, in the selection of benchmark for damage detection, it should be taken into account that the two modal parameters have specific criticalities. Once that the modal parameter has been chosen, values outside the estimated uncertainty range can be considered as alarm triggers.
File in questo prodotto:
File Dimensione Formato  
CustomisedActiveMonitoringSystemForStructuralControlAndMaintenanceOptimisation.pdf

non disponibili

Descrizione: Customised active monitoring system for structural control and maintenance optimisation
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 3.36 MB
Formato Adobe PDF
3.36 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
PostPrint_noEdit_CustomisedActiveMonitoringSystemForStructuralControlAndMaintenanceOptimisation.pdf

Open Access dal 29/01/2021

Descrizione: Customised active monitoring system for structural control and maintenance optimisation - Accepted Manuscript
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 2.36 MB
Formato Adobe PDF
2.36 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2787134