In power electronic designs, preliminary thermal analysis is essential when choosing packages and possible external heatsinks for energy thermal dissipation. In this paper, we describe a methodology for a simple development of a detailed thermal model for a fine pitch plastic Ball Grid Array (BGA) in System-in-Package configuration including one Bipolar-CMOS-DMOS (BCD) device, through the geometric and thermal properties of the power components and layers of the BGA under test. The validation of the proposed thermal model was carried out through a comparison of the simulation results with the experimental data obtained from the thermal analysis through an InfraRed (IR) camera. The absolute estimation error was less than 2°C for a maximum temperature within 100°C, and less than 4.5°C for temperatures above 100°C, with a temperature difference of the case around 50°C.

Thermal modeling of a power ball grid array in system-in-package configuration / Bocca, Alberto; Graziosi, Giovanni; Macii, Alberto. - ELETTRONICO. - (2019), pp. 1-4. (Intervento presentato al convegno 2019 25th International Workshop on Thermal Investigations of ICs and Systems (THERMINIC) tenutosi a Lecco (LC), Italy nel September 25-27, 2019) [10.1109/THERMINIC.2019.8923577].

Thermal modeling of a power ball grid array in system-in-package configuration

Alberto Bocca;Alberto Macii
2019

Abstract

In power electronic designs, preliminary thermal analysis is essential when choosing packages and possible external heatsinks for energy thermal dissipation. In this paper, we describe a methodology for a simple development of a detailed thermal model for a fine pitch plastic Ball Grid Array (BGA) in System-in-Package configuration including one Bipolar-CMOS-DMOS (BCD) device, through the geometric and thermal properties of the power components and layers of the BGA under test. The validation of the proposed thermal model was carried out through a comparison of the simulation results with the experimental data obtained from the thermal analysis through an InfraRed (IR) camera. The absolute estimation error was less than 2°C for a maximum temperature within 100°C, and less than 4.5°C for temperatures above 100°C, with a temperature difference of the case around 50°C.
2019
978-1-7281-2078-2
978-1-7281-2079-9
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2756594
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo