This paper describes a simple sensor which is designed to sample the air and extract the distribution of particulate it contains. The proposed system employs a normal fiberglass filter, a small video camera and a RaspberryPI to process the image and extract the particulate distribution. The fiberglass filter is capable of stopping particulate down to sizes of 2.5 μm, i.e. what is usually refereed to as PM2.5 particulate and employs a small pump to increase the sensitivity. A motor is used to change the filter interested by the particulate and to restart the measurement. Depending on the amount of particulate in the air, the sampling can be restarted every day or more frequently. The proposed system has been characterized by observing the filter using a field-emission electronic microscope showing that the measured distribution is correct. The overall cost of the proposed system is of less than 100$.

Optical solution for particulate distribution estimation / Lombardo, Luca; Parvis, Marco; Angelini, Emma; Grassini, Sabrina. - ELETTRONICO. - 1:(2018), pp. 1-6. (Intervento presentato al convegno 2018 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2018 tenutosi a Royal Sonesta Hotel, usa nel 2018) [10.1109/I2MTC.2018.8409749].

Optical solution for particulate distribution estimation

Lombardo, Luca;Parvis, Marco;Angelini, Emma;Grassini, Sabrina
2018

Abstract

This paper describes a simple sensor which is designed to sample the air and extract the distribution of particulate it contains. The proposed system employs a normal fiberglass filter, a small video camera and a RaspberryPI to process the image and extract the particulate distribution. The fiberglass filter is capable of stopping particulate down to sizes of 2.5 μm, i.e. what is usually refereed to as PM2.5 particulate and employs a small pump to increase the sensitivity. A motor is used to change the filter interested by the particulate and to restart the measurement. Depending on the amount of particulate in the air, the sampling can be restarted every day or more frequently. The proposed system has been characterized by observing the filter using a field-emission electronic microscope showing that the measured distribution is correct. The overall cost of the proposed system is of less than 100$.
2018
9781538622223
File in questo prodotto:
File Dimensione Formato  
IMTC2018_particolato_08409749_SCOPUS.pdf

non disponibili

Descrizione: articolo principale
Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 6.08 MB
Formato Adobe PDF
6.08 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
optical_solution_i2mtc2018.pdf

accesso aperto

Descrizione: Accepted Author Manuscript
Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 4.97 MB
Formato Adobe PDF
4.97 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2712114