Instrumented indentation test is a non-conventional hardness test, relevant for both performing hardness measurement and estimating the elastic modulus. The indentation modulus, which depends on the contact stiffness, estimates the elastic modulus. To evaluate contact stiffness, literature requires to fit force-displacement curve according to mathematical models, which are hardly representative of the curve. This research aims at proposing alternatives, which estimate contact stiffness directly from experimental data. Proposed methods are applied to nano-indentations performed on a reference material and a high-speed bearing steel; indentation modulus is evaluated along with uncertainty contribution of contact stiffness. Comparison with standard methods is provided.

Instrumented indentation test: Contact stiffness evaluation in the nano-range / Maculotti, Giacomo; Genta, Gianfranco; Lorusso, Massimo; Pavese, Matteo; Ugues, Daniele; Galetto, Maurizio. - ELETTRONICO. - Proceedings of the 6th International conference on nanoManufacturing:(2018), pp. 675-682. (Intervento presentato al convegno 6th International Conference on nanoManufacturing tenutosi a London (UK) nel 4-6 July 2018).

Instrumented indentation test: Contact stiffness evaluation in the nano-range

Giacomo Maculotti;Gianfranco Genta;Massimo Lorusso;Matteo Pavese;Daniele Ugues;Maurizio Galetto
2018

Abstract

Instrumented indentation test is a non-conventional hardness test, relevant for both performing hardness measurement and estimating the elastic modulus. The indentation modulus, which depends on the contact stiffness, estimates the elastic modulus. To evaluate contact stiffness, literature requires to fit force-displacement curve according to mathematical models, which are hardly representative of the curve. This research aims at proposing alternatives, which estimate contact stiffness directly from experimental data. Proposed methods are applied to nano-indentations performed on a reference material and a high-speed bearing steel; indentation modulus is evaluated along with uncertainty contribution of contact stiffness. Comparison with standard methods is provided.
File in questo prodotto:
File Dimensione Formato  
Paper 72_new template.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 502.34 kB
Formato Adobe PDF
502.34 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2710934