Concrete mixtures reinforced with a combination of steel rebar and fibers, i.e., Hybrid Reinforced Concretes (HRC), are frequently used in segmental precast tunnel linings. As massive cross-sections are usually adopted in these structures, only the minimum reinforcement is necessary to prevent the brittle failure. To study the brittle/ductile behavior of HRC tunnel segments in bending, the flexural responses of Lightly Reinforced Concrete (LRC) and that of Fiber-Reinforced Concrete (FRC) elements are modelled and combined herein. By means of this combination, the minimum reinforcement of HRC segments can be determined with a new design-by-testing procedure, in which the ductility index DI should be equal to zero. As a result, the minimum hybrid reinforcement can be defined through a linear combination of the minimum area of rebar and the minimum fiber volume fraction of LRC and FRC segments, respectively.

Optimization of hybrid reinforcement in precast concrete linings using numerical analysis / Gorino, Andrea; Fantilli, ALESSANDRO P.; Chiaia, Bernardino. - In: DROGI I MOSTY. - ISSN 1643-1618. - ELETTRONICO. - 16:4(2017), pp. 315-329. [10.7409/rabdim.017.020]

Optimization of hybrid reinforcement in precast concrete linings using numerical analysis

GORINO, ANDREA;FANTILLI, ALESSANDRO P.;CHIAIA, BERNARDINO
2017

Abstract

Concrete mixtures reinforced with a combination of steel rebar and fibers, i.e., Hybrid Reinforced Concretes (HRC), are frequently used in segmental precast tunnel linings. As massive cross-sections are usually adopted in these structures, only the minimum reinforcement is necessary to prevent the brittle failure. To study the brittle/ductile behavior of HRC tunnel segments in bending, the flexural responses of Lightly Reinforced Concrete (LRC) and that of Fiber-Reinforced Concrete (FRC) elements are modelled and combined herein. By means of this combination, the minimum reinforcement of HRC segments can be determined with a new design-by-testing procedure, in which the ductility index DI should be equal to zero. As a result, the minimum hybrid reinforcement can be defined through a linear combination of the minimum area of rebar and the minimum fiber volume fraction of LRC and FRC segments, respectively.
2017
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2696011
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo