Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment. For some instruments, it is not always possible to evaluate each single contributor. Nevertheless, it is possible to evaluate the noise added to the output during the normal use of the instrument. Such noise is defined in ISO 25178 part 605 as “measurement noise”. In this work, the measurement noise is assessed for a commercial point autofocus instrument (Mitaka MLP-3SP), installed in the manufacturing metrology laboratory at The University of Nottingham. The investigation is carried out by areal acquisitions of 100µm×100µm with a 100× magnification objective and a sampling distance of 0.1µm along the x-axis and 1µm along the y-axis. The measurement noise is evaluated by applying established subtraction and averaging methods described elsewhere. The results reveal a maximum calculated value of 20nm (subtraction method) and a minimum of 8nm (subtraction method). An oscillationis observed in the acquired surface topographies, which is due to a thermal drift induced by the air conditioning system. The disturbance can be reduced using the temperature correction tool in the software of the instrument. Experiments performed when the air conditioning system is inactive, showed drift of the instrument due to the temperature which is estimated, in the worst case, as 0.9µm/°C (calculated as Sz/ΔT), over one hour measuring time. The investigation was then repeated applying the temperature correction tool and the evaluation of the measurement noise results in a value of 2nm (both methods).The overall temperature variation, measured in the housing chamber of the instrument, is smaller than 0.1°C during each repeated measurement. In conclusion, the point autofocus instrument shows a clear dependence on the environmental noise. The measurement noise uncertainty contributor in the worst case is estimated to be unoise=20nm when the temperature correction tool is not applied. The use of the built-in temperature correction tool allow temperature correction tool allows the measurement noise uncertainty contributor to be reduced to unoise=2 nm.

Measurement noise of a point autofocus surface topography instrument / Xiaobing, Feng; Quagliotti, Danilo; Maculotti, Giacomo; Syam, Wahyudin P.; Guido, Tosello; Hansen, Hans N.; Galetto, Maurizio; Richard, Leach. - STAMPA. - (2017). (Intervento presentato al convegno 2017 International Conference on Metrology and Properties of Engineering Surfaces tenutosi a Göteborg (Sweden) nel June 26-29 2017).

Measurement noise of a point autofocus surface topography instrument

QUAGLIOTTI, DANILO;MACULOTTI, GIACOMO;Maurizio Galetto;
2017

Abstract

Optical instruments for areal topography measurement can be especially sensitive to noise when scanning is required. Such noise has different sources, including those internally generated and external sources from the environment. For some instruments, it is not always possible to evaluate each single contributor. Nevertheless, it is possible to evaluate the noise added to the output during the normal use of the instrument. Such noise is defined in ISO 25178 part 605 as “measurement noise”. In this work, the measurement noise is assessed for a commercial point autofocus instrument (Mitaka MLP-3SP), installed in the manufacturing metrology laboratory at The University of Nottingham. The investigation is carried out by areal acquisitions of 100µm×100µm with a 100× magnification objective and a sampling distance of 0.1µm along the x-axis and 1µm along the y-axis. The measurement noise is evaluated by applying established subtraction and averaging methods described elsewhere. The results reveal a maximum calculated value of 20nm (subtraction method) and a minimum of 8nm (subtraction method). An oscillationis observed in the acquired surface topographies, which is due to a thermal drift induced by the air conditioning system. The disturbance can be reduced using the temperature correction tool in the software of the instrument. Experiments performed when the air conditioning system is inactive, showed drift of the instrument due to the temperature which is estimated, in the worst case, as 0.9µm/°C (calculated as Sz/ΔT), over one hour measuring time. The investigation was then repeated applying the temperature correction tool and the evaluation of the measurement noise results in a value of 2nm (both methods).The overall temperature variation, measured in the housing chamber of the instrument, is smaller than 0.1°C during each repeated measurement. In conclusion, the point autofocus instrument shows a clear dependence on the environmental noise. The measurement noise uncertainty contributor in the worst case is estimated to be unoise=20nm when the temperature correction tool is not applied. The use of the built-in temperature correction tool allow temperature correction tool allows the measurement noise uncertainty contributor to be reduced to unoise=2 nm.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2695970
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo