Pipe jacking is often used to install pipelines in congested urban areas or river crossings. The applied jacking force needs to be greater than the frictional resistance along the pipe and the face resistance. Lubricant slurries are usually employed to minimize the frictional resistance. Therefore, it is critical to estimate earth pressures acting on shield excavation face correctly. In this paper, the original Protodyakonov’s arch model is modified to calculate the vertical pressure on deeply buried pipes. For shallow burial depth less than 5 m, the Terzaghi arching model is still applicable to estimate the vertical pressure. The soil prism in front of excavation face is divided into different zones to establish the force equilibrium. The calculated earth pressure is applied on top of soil wedges. The proposed analytical solution can analyze the stability of vertical and inclined excavation faces considering the influence of three-dimensional arching effect, as well as the contribution of soil cohesion. In the end, the effectiveness of the developed design framework is assessed by comparing calculations with experimental measurements of earth pressures on excavation face.

Earth pressure on shield excavation face for pipe jacking considering arching effect / Ji, Xinbo; Ni, Pengpeng; Barla, Marco; Zhao, Wen; Mei, Guoxiong. - In: TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY. - ISSN 0886-7798. - STAMPA. - 72:(2018), pp. 17-27. [10.1016/j.tust.2017.11.010]

Earth pressure on shield excavation face for pipe jacking considering arching effect

Barla, Marco;
2018

Abstract

Pipe jacking is often used to install pipelines in congested urban areas or river crossings. The applied jacking force needs to be greater than the frictional resistance along the pipe and the face resistance. Lubricant slurries are usually employed to minimize the frictional resistance. Therefore, it is critical to estimate earth pressures acting on shield excavation face correctly. In this paper, the original Protodyakonov’s arch model is modified to calculate the vertical pressure on deeply buried pipes. For shallow burial depth less than 5 m, the Terzaghi arching model is still applicable to estimate the vertical pressure. The soil prism in front of excavation face is divided into different zones to establish the force equilibrium. The calculated earth pressure is applied on top of soil wedges. The proposed analytical solution can analyze the stability of vertical and inclined excavation faces considering the influence of three-dimensional arching effect, as well as the contribution of soil cohesion. In the end, the effectiveness of the developed design framework is assessed by comparing calculations with experimental measurements of earth pressures on excavation face.
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0886779817304170-main.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2693126
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo