The energy sector is a source of economic and social progress, but it is also the main responsible of air pollution resulting from human activity, mainly from the combustion of fossil fuels and bioenergy. The impacts on atmosphere may be divided into global effects, due to change in concentration of greenhouse gases, and regional/local effects, due to the dispersion of SO2, NOx, particulates and other gases. The aim of this thesis is the development and application of a methodology for calculating the emissions in atmosphere associated with energy management interventions. The methodology aims to characterize and quantify the environmental impacts affecting both the local and global scale. The pollutants involving local effects considered in this study are nitrogen oxides and particulate matter. Globally, the emission of greenhouse gases is considered, by quantifying the equivalent CO2 (CO2eq) emitted. The environmental impact of an energy option is quantified in terms of its emission balance, i.e. by comparing the present situation with one (or more) future scenarios. The study at the local scale also considers the dispersion of pollutants using modelling tools. The methodology is applied to two case studies located in the Italian Metropolitan City of Turin, characterized by different application contexts and different scales of operation. The first case study is represented by a system for the production and conversion of biogas and biomethane. The analysis of global emissions considers four different operating scenarios. The results show a CO2 reduction of 1426 t/y for biogas combustion in full cogeneration mode (generation of both heat and electricity). Biomethane for transports scenario provides a similar result (1379 t/y). If biogas combustion with partial cogeneration is considered (generation of electricity only), the CO2 balance approaches to zero. The evaluation of local impacts is made with two different dispersion models. The application of an Octave-based Gaussian model provides an average increase of concentration both for NOx and TSP, in the order of units of g/m3. The results of CALPUFF model simulations show a slight decrease of concentration in the order of 10-2 g/m3. The second case study consists of a potential extension of the district heating network in the urban area of Turin. The production of local emissions is calculated considering the operation of the main power plants in response to the estimated heat demand. Avoided emissions are calculated simulating the heat production of centralized residential heaters. The results of CALPUFF model simulations show a potential reduction of NOx average concentration between 1 and 6 g/m3. The results of global emissions show an unfavorable balance in the order of 104 t/y of CO2, that varies depending on the assumptions on the emission factors of the power units. A comprehensive final discussion is reported after the analysis of the two case studies. The calculation of two indicators (the “thermal benefit vs. local emission indicator” and the “local to global emission ratio”) is also included to discuss a possible standardization of the proposed methodology. This study provides important information on the effects on air quality resulting from the modification of the energetic management of an area or settlement. The employed methodology is consistent and comprehensive in identifying the potential optimal solutions for energy production and management, as well as identifying the consequences to a given scenario under an environmental point of view.

Development and application of a comprehensive methodology for the analysis of global and local emissions of energy systems / Ravina, Marco. - (2016). [10.6092/polito/porto/2674649]

Development and application of a comprehensive methodology for the analysis of global and local emissions of energy systems

RAVINA, MARCO
2016

Abstract

The energy sector is a source of economic and social progress, but it is also the main responsible of air pollution resulting from human activity, mainly from the combustion of fossil fuels and bioenergy. The impacts on atmosphere may be divided into global effects, due to change in concentration of greenhouse gases, and regional/local effects, due to the dispersion of SO2, NOx, particulates and other gases. The aim of this thesis is the development and application of a methodology for calculating the emissions in atmosphere associated with energy management interventions. The methodology aims to characterize and quantify the environmental impacts affecting both the local and global scale. The pollutants involving local effects considered in this study are nitrogen oxides and particulate matter. Globally, the emission of greenhouse gases is considered, by quantifying the equivalent CO2 (CO2eq) emitted. The environmental impact of an energy option is quantified in terms of its emission balance, i.e. by comparing the present situation with one (or more) future scenarios. The study at the local scale also considers the dispersion of pollutants using modelling tools. The methodology is applied to two case studies located in the Italian Metropolitan City of Turin, characterized by different application contexts and different scales of operation. The first case study is represented by a system for the production and conversion of biogas and biomethane. The analysis of global emissions considers four different operating scenarios. The results show a CO2 reduction of 1426 t/y for biogas combustion in full cogeneration mode (generation of both heat and electricity). Biomethane for transports scenario provides a similar result (1379 t/y). If biogas combustion with partial cogeneration is considered (generation of electricity only), the CO2 balance approaches to zero. The evaluation of local impacts is made with two different dispersion models. The application of an Octave-based Gaussian model provides an average increase of concentration both for NOx and TSP, in the order of units of g/m3. The results of CALPUFF model simulations show a slight decrease of concentration in the order of 10-2 g/m3. The second case study consists of a potential extension of the district heating network in the urban area of Turin. The production of local emissions is calculated considering the operation of the main power plants in response to the estimated heat demand. Avoided emissions are calculated simulating the heat production of centralized residential heaters. The results of CALPUFF model simulations show a potential reduction of NOx average concentration between 1 and 6 g/m3. The results of global emissions show an unfavorable balance in the order of 104 t/y of CO2, that varies depending on the assumptions on the emission factors of the power units. A comprehensive final discussion is reported after the analysis of the two case studies. The calculation of two indicators (the “thermal benefit vs. local emission indicator” and the “local to global emission ratio”) is also included to discuss a possible standardization of the proposed methodology. This study provides important information on the effects on air quality resulting from the modification of the energetic management of an area or settlement. The employed methodology is consistent and comprehensive in identifying the potential optimal solutions for energy production and management, as well as identifying the consequences to a given scenario under an environmental point of view.
2016
File in questo prodotto:
File Dimensione Formato  
Thesis Marco Ravina_FINAL.pdf

accesso aperto

Descrizione: Tesi completa
Tipologia: Tesi di dottorato
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 37.09 MB
Formato Adobe PDF
37.09 MB Adobe PDF Visualizza/Apri