In this paper, a 12-phase asymmetrical induction machine is proposed as embedded starter/alternator connected to the high-pressure shaft of an open rotor jet engine. The main focus of the paper is on the modeling and control of the multiphase machine in order to verify its operation, including overload capabilities and post fault operations. The machine control uses a direct flux vector control scheme based on a multi-three-phase approach, where each three-phase winding set is independently controlled. In this way, the fault tolerant behavior of the drive system is improved. The proposed solution has been experimentally validated with a multi-modular power converter and a reduced scaled machine prototype (10 kW, 6000 rpm). The overload capability has been verified in generation mode for different speed values and torque up to the 150% the rated value. The sudden transition between healthy and faulty modes is reported for open-phases fault.

Asymmetrical twelve-phase induction starter/generator for more electric engine in aircraft / Rubino, Sandro; Bojoi, IUSTIN RADU; Cavagnino, Andrea; Vaschetto, Silvio. - (2016), pp. 1-8. (Intervento presentato al convegno 2016 IEEE Energy Conversion Congress and Exposition (ECCE) tenutosi a Milwaukee, WI, USA nel 18-22 Sept. 2016) [10.1109/ECCE.2016.7854889].

Asymmetrical twelve-phase induction starter/generator for more electric engine in aircraft

RUBINO, SANDRO;BOJOI, IUSTIN RADU;CAVAGNINO, ANDREA;VASCHETTO, SILVIO
2016

Abstract

In this paper, a 12-phase asymmetrical induction machine is proposed as embedded starter/alternator connected to the high-pressure shaft of an open rotor jet engine. The main focus of the paper is on the modeling and control of the multiphase machine in order to verify its operation, including overload capabilities and post fault operations. The machine control uses a direct flux vector control scheme based on a multi-three-phase approach, where each three-phase winding set is independently controlled. In this way, the fault tolerant behavior of the drive system is improved. The proposed solution has been experimentally validated with a multi-modular power converter and a reduced scaled machine prototype (10 kW, 6000 rpm). The overload capability has been verified in generation mode for different speed values and torque up to the 150% the rated value. The sudden transition between healthy and faulty modes is reported for open-phases fault.
2016
978-1-5090-0737-0
978-1-5090-0737-0
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2665670
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo