The paper focuses on extending a recently proposed damage localization method, previously devised for structures subjected to a known input, to ambient vibrations induced by an unknown wind excitation. Wind induced vibrations in long-span bridges can be recorded without closing the infrastructure to traffic, providing useful data for health monitoring purposes. One major problem in damage identification of large civil structures is the scarce data recorded on damaged real structures. A detailed finite element model, able to correctly and reliably reproduce the real structure behavior under ambient excitation can be an invaluable tool, enabling the simulation of several different damage scenarios to test the performance of any monitoring system. In this work a calibrated finite element model of an existing long-span suspension bridge is used to simulate the structural response to wind actions. Several damage scenarios are simulated with different location and severity of damage to check the sensitivity of the adopted identification method. The sensitivity to the length and noise disturbances of recorded data are also investigated. © 2016 Vilnius Gediminas Technical University (VGTU) Press Technika.

Wind-driven damage localization on a suspension bridge / Domaneschi, Marco; Limongelli, M. P.; Martinelli, L.. - In: THE BALTIC JOURNAL OF ROAD AND BRIDGE ENGINEERING. - ISSN 1822-427X. - 11:1(2016), pp. 11-21. [10.3846/bjrbe.2016.02]

Wind-driven damage localization on a suspension bridge

DOMANESCHI, MARCO;
2016

Abstract

The paper focuses on extending a recently proposed damage localization method, previously devised for structures subjected to a known input, to ambient vibrations induced by an unknown wind excitation. Wind induced vibrations in long-span bridges can be recorded without closing the infrastructure to traffic, providing useful data for health monitoring purposes. One major problem in damage identification of large civil structures is the scarce data recorded on damaged real structures. A detailed finite element model, able to correctly and reliably reproduce the real structure behavior under ambient excitation can be an invaluable tool, enabling the simulation of several different damage scenarios to test the performance of any monitoring system. In this work a calibrated finite element model of an existing long-span suspension bridge is used to simulate the structural response to wind actions. Several damage scenarios are simulated with different location and severity of damage to check the sensitivity of the adopted identification method. The sensitivity to the length and noise disturbances of recorded data are also investigated. © 2016 Vilnius Gediminas Technical University (VGTU) Press Technika.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2664602
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo