This paper proposes a standstill method for identification of the magnetic model of synchronous reluctance motors (SyRMs). The saturation and cross-saturation effects are properly taken into account. The motor is fed by an inverter with a short sequence of bipolar voltage pulses that are first applied on the rotor d- and q-axes separately and then simultaneously on both the axes. The stator flux linkages are computed by integrating the induced voltages. Using the current and flux samples, the parameters of an algebraic magnetic model are estimated by means of linear least squares. The proposed method is robust against errors in the stator resistance and inverter voltage, due to the high test voltages (of the order of the rated voltage). The fitted model matches very well with the reference saturation characteristics, measured using a constant-speed method, and enables extrapolation outside the sample range. The method was tested with a 2.2-kW SyRM, whose shaft was uncoupled from any mechanical load, which is the most demanding condition for this method. The proposed method can be used for automatic self-commissioning of sensorless SyRM drives at standstill.

Sensorless self-commissioning of synchronous reluctance motors at standstill without rotor locking / Hinkkanen, Marko; Pescetto, Paolo; Molsa, Eemeli; Saarakkala, Seppo E.; Pellegrino, GIAN - MARIO LUIGI; Bojoi, IUSTIN RADU. - In: IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS. - ISSN 0093-9994. - ELETTRONICO. - 53:3(2017), pp. 2120-2129. [10.1109/TIA.2016.2644624]

Sensorless self-commissioning of synchronous reluctance motors at standstill without rotor locking

PESCETTO, PAOLO;PELLEGRINO, GIAN - MARIO LUIGI;BOJOI, IUSTIN RADU
2017

Abstract

This paper proposes a standstill method for identification of the magnetic model of synchronous reluctance motors (SyRMs). The saturation and cross-saturation effects are properly taken into account. The motor is fed by an inverter with a short sequence of bipolar voltage pulses that are first applied on the rotor d- and q-axes separately and then simultaneously on both the axes. The stator flux linkages are computed by integrating the induced voltages. Using the current and flux samples, the parameters of an algebraic magnetic model are estimated by means of linear least squares. The proposed method is robust against errors in the stator resistance and inverter voltage, due to the high test voltages (of the order of the rated voltage). The fitted model matches very well with the reference saturation characteristics, measured using a constant-speed method, and enables extrapolation outside the sample range. The method was tested with a 2.2-kW SyRM, whose shaft was uncoupled from any mechanical load, which is the most demanding condition for this method. The proposed method can be used for automatic self-commissioning of sensorless SyRM drives at standstill.
File in questo prodotto:
File Dimensione Formato  
Pescetto_TIA2016_Sensorless_Self_Commissioning.pdf

accesso aperto

Tipologia: 2. Post-print / Author's Accepted Manuscript
Licenza: PUBBLICO - Tutti i diritti riservati
Dimensione 678.47 kB
Formato Adobe PDF
678.47 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2660144
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo