Many pharmaceutical products are obtained via freeze-drying of liquid solutions to obtain stable long lasting preparations. The freeze-dry process produces porous cakes whose structure strongly depends on the freezing phase, so that monitoring and optimizing this phase can help both reducing the product cost and insuring its constant quality. Nowadays the optimization is usually performed by determining the cake mass transfer coefficient via a costly process in pilot plants, while the quality is assured only by controlling the process conditions. This paper describes an alternative way of approximately estimat-ing the mass transfer coefficient, which is based on the observation of the product structure by a simple electron microscope followed by a frequency domain imaging process. While the process has been designed and characterized specifically for pharmaceutical products, the proposed approach can be used in several other fields where the characteristics of porous material have to be monitored.

Frequency domain image analysis for the characterization of porous products / Grassini, Sabrina; Pisano, Roberto; Barresi, Antonello; Angelini, EMMA PAOLA MARIA VIRGINIA; Parvis, Marco. - In: MEASUREMENT. - ISSN 0263-2241. - STAMPA. - 94:(2016), pp. 515-522. [10.1016/j.measurement.2016.08.031]

Frequency domain image analysis for the characterization of porous products

GRASSINI, Sabrina;PISANO, ROBERTO;BARRESI, Antonello;ANGELINI, EMMA PAOLA MARIA VIRGINIA;PARVIS, Marco
2016

Abstract

Many pharmaceutical products are obtained via freeze-drying of liquid solutions to obtain stable long lasting preparations. The freeze-dry process produces porous cakes whose structure strongly depends on the freezing phase, so that monitoring and optimizing this phase can help both reducing the product cost and insuring its constant quality. Nowadays the optimization is usually performed by determining the cake mass transfer coefficient via a costly process in pilot plants, while the quality is assured only by controlling the process conditions. This paper describes an alternative way of approximately estimat-ing the mass transfer coefficient, which is based on the observation of the product structure by a simple electron microscope followed by a frequency domain imaging process. While the process has been designed and characterized specifically for pharmaceutical products, the proposed approach can be used in several other fields where the characteristics of porous material have to be monitored.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2652220
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo