Even under the powerful thrust of 20–20–20 measures, solar thermal systems are experiencing a slow-down in their development in most EU countries. One reason is their traditional confinement to sanitary hot water (SHW) production; another one is the growing competition with photovoltaic (PV) systems. In order to widen the use of solar thermal collectors, they should also be able to contribute to space heating and cooling and become Multi-Purpose Solar Thermal Systems (MPSTS). This paper addresses the issue of optimal sizing of MPSTS. The criterion adopted is based on maximization of Net Present Value and has been applied to some cities in Italy and in Pakistan with diverse climate conditions. Results show that optimal thermal collector areas per peak cooling demand (Ac/Pc) can be conveniently expressed as a function of Peak Heating to Cooling Ratio (Ph/Pc). Optimum Ac/Pc varies between 3 and 5 m2/ kWc and decreases with increasing Ph/Pc. The paper also analyses and compares a MPSTS with a multi-purpose PV-based heat pump system using a traditional one (boiler and compression chiller) as reference. Results show that steadily decreasing prices have made PV systems more favorable, even without consideration of public subsidies.

Cost-effectiveness of multi-purpose solar thermal systems and comparison with PV-based heat pumps / Ghafoor, A.; Fracastoro, GIOVANNI VINCENZO. - In: SOLAR ENERGY. - ISSN 0038-092X. - 113:(2015), pp. 272-280. [10.1016/j.solener.2015.01.015]

Cost-effectiveness of multi-purpose solar thermal systems and comparison with PV-based heat pumps

FRACASTORO, GIOVANNI VINCENZO
2015

Abstract

Even under the powerful thrust of 20–20–20 measures, solar thermal systems are experiencing a slow-down in their development in most EU countries. One reason is their traditional confinement to sanitary hot water (SHW) production; another one is the growing competition with photovoltaic (PV) systems. In order to widen the use of solar thermal collectors, they should also be able to contribute to space heating and cooling and become Multi-Purpose Solar Thermal Systems (MPSTS). This paper addresses the issue of optimal sizing of MPSTS. The criterion adopted is based on maximization of Net Present Value and has been applied to some cities in Italy and in Pakistan with diverse climate conditions. Results show that optimal thermal collector areas per peak cooling demand (Ac/Pc) can be conveniently expressed as a function of Peak Heating to Cooling Ratio (Ph/Pc). Optimum Ac/Pc varies between 3 and 5 m2/ kWc and decreases with increasing Ph/Pc. The paper also analyses and compares a MPSTS with a multi-purpose PV-based heat pump system using a traditional one (boiler and compression chiller) as reference. Results show that steadily decreasing prices have made PV systems more favorable, even without consideration of public subsidies.
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/2631777
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo