The analysis of the carotid wall is of paramount importance in clinical practice. In fact, the intima-media thickness is a risk index for some of the most severe acute cerebrovascular pathologies; hence, the need for an accurate segmentation of the different layers of the carotid artery. In the past ten years, a wide variety of algorithms for the carotid tunica segmentation have been proposed, but they require a certain degree of user interaction. In this paper we propose a novel approach to the completely user-independent segmentation of the carotid artery wall. Our algorithm has been designed for the extraction of the intima and media layers of the distal carotid wall, based on ultrasonic B-mode images. We evaluated the performance of the algorithm on a set of 63 images and compared the automatic segmentation to that traced by a trained operator. We obtained a mean error lower than 1.3 pixel both on the intima and media layers, which is comparable to that obtained by means of operator dependent techniques

CULEX - Completely User-independent Layers EXtraction: Ultrasonic carotid artery images segmentation / Delsanto, S.; Molinari, Filippo; Giustetto, P.; Liboni, W.; Badalamenti, S.. - ELETTRONICO. - (2005), pp. 6468-6471. (Intervento presentato al convegno 27th Annual Internation Conference of the IEEE EMBS tenutosi a Shangai, Cina nel 1 - 4 Settembre) [10.1109/IEMBS.2005.1615980].

CULEX - Completely User-independent Layers EXtraction: Ultrasonic carotid artery images segmentation

MOLINARI, FILIPPO;
2005

Abstract

The analysis of the carotid wall is of paramount importance in clinical practice. In fact, the intima-media thickness is a risk index for some of the most severe acute cerebrovascular pathologies; hence, the need for an accurate segmentation of the different layers of the carotid artery. In the past ten years, a wide variety of algorithms for the carotid tunica segmentation have been proposed, but they require a certain degree of user interaction. In this paper we propose a novel approach to the completely user-independent segmentation of the carotid artery wall. Our algorithm has been designed for the extraction of the intima and media layers of the distal carotid wall, based on ultrasonic B-mode images. We evaluated the performance of the algorithm on a set of 63 images and compared the automatic segmentation to that traced by a trained operator. We obtained a mean error lower than 1.3 pixel both on the intima and media layers, which is comparable to that obtained by means of operator dependent techniques
2005
0-7803-8741-4
File in questo prodotto:
Non ci sono file associati a questo prodotto.
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1414063
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo