A number of poly(ethyleneglycol)- and poly(propyleneglycol)- α, ω-diacrylates, with different MW in the range 200-2000, were subjected to UV curing as thin films and the properties of the obtained crosslinked polymers were investigated. The total double bond conversion was determined by Fourier transform infrared spectroscopy (FTIR). Direct scanning calorimetry (DSC), thermal mechanical analysis (TMA) and dynamic-mechanical thermal analysis (DMTA) were used to evaluate the thermal and dynamic-mechanical behaviour of the networks obtained. The double bond conversion was found to be always complete, with the exception of the lowest MW oligomers. Tg values were found to decrease with increasing the MW of the oligomers used for both series. The equilibrium swelling in water was found to increase with increasing MW that is with decreasing the crosslinking density of the network. Mixtures of different oligomers with a typical epoxyacrylate resin were also examined. A sharp increase of the total double bond conversion in the presence of the oligomers was observed. The Tg values of the obtained films were found to decrease with increasing oligomer MW in agreement with the data obtained by using the pure acrylate oligomers. The results obtained are discussed in terms of the crosslinking density of the networks formed in the curing process.

Investigation on the structure-property relationships for films obtained from UV curable coatings / Priola, Aldo; Gozzelino, Giuseppe; Ferrero, Franco; Malucelli, Giulio. - In: PROGRESS IN ORGANIC COATINGS. - ISSN 0300-9440. - STAMPA. - 22:1-4(1993), pp. 301-314. [10.1016/0033-0655(93)80032-6]

Investigation on the structure-property relationships for films obtained from UV curable coatings

PRIOLA, ALDO;GOZZELINO, Giuseppe;FERRERO, Franco;MALUCELLI, Giulio
1993

Abstract

A number of poly(ethyleneglycol)- and poly(propyleneglycol)- α, ω-diacrylates, with different MW in the range 200-2000, were subjected to UV curing as thin films and the properties of the obtained crosslinked polymers were investigated. The total double bond conversion was determined by Fourier transform infrared spectroscopy (FTIR). Direct scanning calorimetry (DSC), thermal mechanical analysis (TMA) and dynamic-mechanical thermal analysis (DMTA) were used to evaluate the thermal and dynamic-mechanical behaviour of the networks obtained. The double bond conversion was found to be always complete, with the exception of the lowest MW oligomers. Tg values were found to decrease with increasing the MW of the oligomers used for both series. The equilibrium swelling in water was found to increase with increasing MW that is with decreasing the crosslinking density of the network. Mixtures of different oligomers with a typical epoxyacrylate resin were also examined. A sharp increase of the total double bond conversion in the presence of the oligomers was observed. The Tg values of the obtained films were found to decrease with increasing oligomer MW in agreement with the data obtained by using the pure acrylate oligomers. The results obtained are discussed in terms of the crosslinking density of the networks formed in the curing process.
File in questo prodotto:
File Dimensione Formato  
1993 Priola POC Investigation structure-property relationships.pdf

non disponibili

Tipologia: 2a Post-print versione editoriale / Version of Record
Licenza: Non Pubblico - Accesso privato/ristretto
Dimensione 557.54 kB
Formato Adobe PDF
557.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Pubblicazioni consigliate

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11583/1402167